Page 71 of 72
SYMPTOM: PRODUCT HOT
Possible Cause: Compressor Will Not Run.
WHAT TO CHECK SOLUTION
1. Is the vender plugged in?
YES
1. NO, plug it in.
2. Is the compressor power cord plugged in?
YES
2. NO, plug it in.
3. Is the temperature control on?
YES
3. NO, turn it on.
4. Is there power at the wall outlet?
YES
4. NO, consult an electrician.
5. Is the circuit breaker or fuse correct?
YES
5. NO, replace or reset.
6. Is the vender power cord good?
YES
6. NO, replace.
7. Is the compressor power cord good?
YES
7. NO, replace.
8. Is the temperature control bulb located properly?
YES
8. NO, correct.
9. Is the temperature control operational?
YES
9. NO, replace.
10. Is the thermal overload operational?
YES
10. NO, replace.
11. Is the start relay operational?
YES
11. NO, replace.
12. Is the compressor operational?
YES
12. NO, replace.
13. Consult the Dixie-Narco Factory Service at
1-800-688-9090.
Note: Have the vender model and serial number available.