EasyManua.ls Logo

Dixie Narco SIID - NF - Note Factor; CR - Change Rules; BILL - Set Bills Only; LIM - Limited Access Menu

Default Icon
14 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SIID CONTROLLER PROGRAMING
Page 6 of 13
NF - NOTE FACTOR (for use with foreign note acceptors only)
Will only be present in menu if SET BILLS ONLY is programmed to "BILLS YES".
Some foreign note acceptors that use a pulsed signal to indicate the value of the note being accepted must have the
value of that pulse (the note factor) programmed in the vender. The SIID will determine the value of the note inserted
by multiplying the number of pulses counted by the Note Factor programmed.
To show the current Note Factor "NF" condition:
Press any select button and the current value will be displayed.
To change the Note Factor "NF" condition:
Press and hold any select button. The Note Factor will increment or decrement from 100 to 10,000. To
change from increment to decrement, release the select button and press it again. Note: 100 is $1.00 in
domestic use.
NOTE: The decimal point position will be communicated by the coin mech to the SIID control board.
Press & hold select buttons 1 & 2 simultaneously to move to the next item on the menu.
CR - CHANGE RULES (for use with foreign L-Plus coin mechs only)
Some countries have coin mechs that do not use all three coin tubes. This would not allow the SIID to come out of
exact change mode. To accommodate this, the Change Rules section allows the SIID to be programmed to use the
tubes necessary for the SIID to not be in an exact change mode.
To show the current Change Rules condition, press any select button and the display will show "ABC", indicating
tubes A, B, and C must have change. "A" refers to the tube on the left, "C" refers to the tube on the right, and "B"
refers to the tube in the middle.
To change the Change Rule Condition:
Select Button 1: When pressed, enables and disables Tube A.
Select Button 2: When pressed, enables and disables Tube B.
Select Button 3: When pressed, enables and disables Tube C.
Press and hold select buttons 1 & 2 simultaneously to move to the next item on the menu.
BILL - SET BILLS ONLY (SIID Only)
This function is used to program the vender to take bills only.
To show the current "BILL" condition: Press select button 1 and the current condition will be displayed.
To change the "BILL" condition:
Press Select Button 1: When pressed, enables "BILLS YES" mode. You no longer need to use a changer;
the controller will operate with bills only.
Press Select Button 2: When pressed, enables "BILLS NO" mode. You need to use a changer; the
controller will not operate the note acceptor without a changer.
Press and hold select buttons 1 & 2 simultaneously to move to the next item on the menu.
LIM - LIMITED ACCESS MENU
This function is used to program the vender to use the Limited Access Features. To move to Secondary Price Menu
"SEC", press & hold select buttons 1 & 2 simultaneously, to enter the sub-menu press select button 1. The following
are sub-menus of Limited Access Menu: "LAOS" ,"LAOD" ,"PER1" ,"PER2", and "RTN".