Safety instructions RMDT10.5(X)T
18
A
NOTICE! Damage hazard
Only hold the device at the body of the device during transport. Never
hold the device at the absorber unit, the cooling fins, the gas pipes,
the door or the control panel.
Make sure that the device circuit is not damaged during
transportation. The refrigerant in the device circuit is highly
flammable.
In the event of any damage to the device circuit (smell of ammonia):
Switch off the device if applicable.
Avoid naked flames and sparks.
Air the room well.
Do not install the device near naked flames or other heat sources (heat-
ers, direct sunlight, gas ovens etc.).
Danger of overheating!
Always ensure sufficient ventilation so that the heat generated during
operation can dissipate. Make sure that the device is sufficiently far
away from walls and other objects so that the air can circulate.
Check that the voltage specification on the type plate is the same as
that of the power supply.
Do not open the refrigerant circuit under any circumstances.
Only use the AC connection cable supplied to connect the device to
the AC mains.
Only use cables with a suitable size.
Never pull the plug out of the socket by the connection cable.
The device may not be exposed to rain.

Other manuals for Dometic 10 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dometic 10 Series and is the answer not in the manual?

Dometic 10 Series Specifications

General IconGeneral
TypeAbsorption
Energy Source12V DC, 230V AC, Gas
FeaturesLED lighting
Climate ClassT (Tropical)
DoorSingle door, left or right hinged (model dependent)

Related product manuals