3
INSTALLATION INSTRUCTIONS
System Requirements:
2 GPM (10.6 lpm) or larger water pump.
1/2-inch (12.7 mm) water line terminating in 1/2-inch MPT tting (to connect to toilet water supply hose).
4-bolt oor (closet) ange. SeaLand anges available include 3-inch spigot, socket, MPT, or 45-degree swivel
socket.
12 VDC through 2-amp fuse or circuit breaker. Use 14-gauge stranded copper wire.
STEP 1: Carefully unpack the toilet bowl, rear access lid and oor ange adapter. CAUTION: HANDLE THE VIT-
REOUS CHINA TOILET AND ACCESS LID WITH CARE. SET THE LID IN AN AREA WHERE IT CANNOT BE
BROKEN. PLACE LID ON TOILET ONLY AFTER TOILET INSTALLATION IS COMPLETE.
STEP 2: Position the china bowl in the space intended. Conrm that adequate clearance is available for using the
ush handle and opening the seat and lid.
STEP 3: Mark the oor at the rear corners of the toilet bowl (g. 1). Measure the distance between the two marks
and divide by 2 to nd the toilet centerline. Mark the oor at the rear wall for the centerline.
STEP 4: Place a carpenter’s square against the back wall, and draw a center line on the oor at least 14 inches
(356 mm) long (g. 2). Mark the centerline for the oor ange at 11-1/4 inches (286 mm) from the wall (g. 3).
Fig. 2
Fig. 1
TOILET DIMENSIONS
MODEL 3210
Dimensions may vary
±3/8-inch (13mm).
Fig. 3