Read these instructions carefully. These
instructions MUST stay with this product.
USA
SERVICE OFFICE
Dometic Corporation
1120 North Main Street
Elkhart, IN 46514
CANADA
Dometic Corporation
46 Zatonski, Unit 3
Brantford, ON N3T 5L8
CANADA
SERVICE CENTER &
DEALER LOCATIONS
Please Visit:
www.eDometic.com
RECORD THIS INFORMATION FOR FUTURE
REFERENCE:
Model Number
Serial Number
Date Purchased
This Unit is designed for OEM installation. All initial installations must be approved by Dometic Corporation.
Roof Top Unit Used With 3105007.XXX OR 3105935.XXX Return Air Grille
Description Blizzard NXT
TM
Model
Electronic Control Kit Thermostat Optional Indoor
Temperature
Sensor
Air Conditioner
CCC 2 Controls H540315
H540316
3312020.000 3314082.000 CCC 2-Blk
3314082.011 CCC 2-Wht
3311931.000-20′
3311931.012-40′
3311931.020-60′
LCD SZ Controls H540315
H540316
3313189.000 C/F-Wht
3313189.015 C/F-Blk
3313192.000 C/F-Wht
3313192.019 C/F-Blk
N/A
REVISION A
Form No. 3316207.000 09/16
(French 3316208.000_A)
©2016 Dometic Corporation
LaGrange, IN 46761
INSTALLATION
INSTRUCTIONS
Question and Answer IconNeed help?

Do you have a question about the Dometic Blizzard NXT H540315 and is the answer not in the manual?

Dometic Blizzard NXT H540315 Specifications

General IconGeneral
Model NumberH540315
Cooling Capacity15, 000 BTU/h
Voltage115 V
Frequency60 Hz
RefrigerantR410A
TypeRooftop Air Conditioner
Power Consumption1750 W

Summary

Important Safety Instructions

Recognize Safety Information

Explains the safety alert symbol and its role in preventing injury or death.

Understand Signal Words

Defines signal words (WARNING, CAUTION, NOTICE) to communicate hazard levels and safety messages.

Supplemental Directives

Stresses the importance of reading and understanding all instructions to prevent possible injury or death.

General Safety Messages

Warns against unqualified installation, product modification, and unauthorized accessory additions.

Specifications

Roof Requirements

Details the required roof opening dimensions and structural support frame for unit installation.

Installation Instructions

Choosing Proper Location For Unit

Guidelines for selecting the optimal roof location based on RV size, insulation, and comfort needs.

Roof Preparation

Instructions for safely cutting the roof opening, preparing the area, and securing the unit.

Air Distribution Duct Sizing & Design

Requirements for air distribution system design, including duct sizing, insulation, and sealing.

Wiring Requirements

Procedures for routing and connecting 120 Vac, 12 Vdc power, and thermostat communication cables.

Choosing Thermostat Location

Guidelines for selecting an effective thermostat mounting location for comfortable RV temperature control.

Thermostat, Optional Indoor Temperature Sensor & Thermostat Communication Cable Installation

Step-by-step guide for installing thermostats, indoor sensors, and connecting communication wiring.

Placing Unit On Roof

Instructions for safely lifting and positioning the air conditioner unit onto the prepared roof opening.

Installing Unit

Steps for securing the unit, aligning gaskets, and installing internal components like the divider plate.

LCD SZ System Low Voltage Wire Connections

Specific instructions for connecting low voltage wires to the LCD SZ system electronic control box.

CCC 2 System Low Voltage Wire Connections

Specific instructions for connecting low voltage wires to the CCC 2 system electronic control box.

120 Vac Power Supply Connection

Procedures for safely connecting the 120 Vac power supply to the unit's junction box.

System Configuration

Guide to configuring the system using dip switches for optimal operation based on installed options.

Installing Return Air Cover

Steps for attaching the return air cover, filter grille, and hole plugs to the installed unit.

(CCC 2 System Only) Reset & Checkout

Procedures for performing a system reset after configuration and conducting a functional checkout.

(CCC 2 System Only) Furnace /Aqua Temperature Differential Setting

Instructions for setting the temperature differential for furnace or aqua heating system operation.

General Information

Heat Gain

Explains factors influencing RV heat gain and preventative measures to improve AC performance.

Condensation

Discusses condensation formation on interior surfaces related to air conditioning operation and humidity.

Wiring Diagrams

Simple RV Wiring Diagram

Illustrates the general wiring layout for the air conditioner within a typical RV electrical system.

Unit Wiring Diagrams

Provides detailed wiring diagrams specific to Dometic air conditioner unit models.

Electronic Control Kit Wiring Diagrams

Wiring diagrams for various electronic control kits used with the air conditioner system.

Related product manuals