Fixing with the safety seat belt
Proceed as shown (fig. 9, page 7).
Fixing with luggage tighteners
Proceed as shown (fig. 0, page 8).
6.7 Selecting the temperature unit
Proceed as shown (fig. a, page 8).
6.8 Setting the temperature
Proceed as shown (fig. b, page 8).
6.9 Setting the display‘s brightness
Proceed as shown (fig. c, page 9).
I
6.10 Using the battery monitor
If the cooler is operated when the vehicle ignition is switched off, the cooler switches
off automatically as soon as the supply voltage falls below a set level. The cooler will
switch back on once the battery has been recharged to the restart voltage level.
A
In “HIGH” mode, the battery monitor responds faster than at the levels “LOW” and
“MED” (see the following table).
NOTE
The factory setting of brightness of the display is d0 (default).
If a fault occurs, the brightness automatically reverts to brightness d0
(default). After troubleshooting the set brightness is reactivated.
NOTICE! Danger of damage
When switched off by the battery monitor, the battery will no longer be
fully charged. Avoid starting repeatedly or operating current consumers
without longer charging phases. Ensure that the battery is recharged.
Battery monitor mode LOW MED HIGH
Switch-off voltage at 12 V
10.1 V 11.4 V 11.8 V
Restart voltage at 12 V
11.1 V 12.2 V 12.6 V
DometicCDF2-36_OPM_4445102509_EMEA17_202x-xx-xx.book Page 20 Thursday, September 15, 2022 2:57 PM