CDF236 Operation
21
I
Setting the battery monitor mode
Proceed as shown (fig. d, page 10).
6.11 Defrosting the cooler
Humidity can form frost in the interior of the cooling device or on the vaporiser. This
reduces the cooling capacity. Defrost the device in good time to avoid this.
A
To defrost the cooler, proceed as follows:
Take out the contents of the cooling device.
If necessary, place them in another cooling device to keep them cool.
Switch off the device.
Leave the cover open.
Wipe off the defrosted water.
6.12 Replacing the plug fuse (12/24 V)
Replace the defective fuse with a new fuse of the same type and rating.
Proceed as shown (fig. e, page 11).
Switch-off voltage at 24 V
21.5 V 24.1 V 24.6 V
Restart voltage at 24 V
23.0 V 25.3 V 26.2 V
NOTE
When the cooler is supplied by the starter battery, select the battery
monitor mode “HIGH”. If the cooler is connected to a supply battery,
the battery monitor mode “LOW” will suffice.
If you wish to operate the cooler from the AC mains, set the battery
monitor to the “LOW” position.
NOTICE! Danger of damaging the device
Never use hard or pointed tools to remove ice or to loosen objects
which have frozen in place.
Battery monitor mode LOW MED HIGH