EasyManua.ls Logo

Dometic CFX3 - Page 36

Dometic CFX3
104 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EN
Troubleshooting CFX3
36
Alert messages
E.g. see
fig. p A, page 15.
Alert message Description Possible cause Suggested remedy
!ALERT - Lid open
> 3min
Lid open more
than 3 minutes
Lid not fully
latched
•Internal fault
Check lid latched fully
Call the customer
service.
!ALERT - Voltage
low
The device has
stopped working
on DC due to low
voltage
Insufficient supply
voltage
Battery voltage is
too low
Battery protec-
tion is set too high
Check voltage drop
from battery to power
outlet and increase wir-
ing gauge if necessary
Test the battery and
charge as needed
Select a lower battery
protection setting
The device has
stopped working
on DC due to
abnormally high
voltage >31.5 V
(unlikely event –
for electronics
protection only –
uses same alert
message as low
voltage above)
Wrong DC supply
voltage
specification
Faulty supply
voltage
•Internal fault
Ensure DC supply volt-
age specification
matches CFX3 product
rating label
Check DC voltage
supply and repair or
replace if faulty
Call the customer
service.

Table of Contents

Related product manuals