R
Robin AllenAug 27, 2025
Why is my Dometic Refrigerator not cooling well on gas?
- MMatthew ScottAug 27, 2025
If your Dometic Refrigerator operates in gas mode but does not cool properly, the flue baffle is likely out of place or damaged.







Why is my Dometic Refrigerator not cooling well on gas?
If your Dometic Refrigerator operates in gas mode but does not cool properly, the flue baffle is likely out of place or damaged.
Why is my Dometic DM2652 freezing food?
If the fresh food compartment in your Dometic Refrigerator is freezing, it could be because the thermistor is not operating within the proper temperature range, or there is a short or a failed circuit in the lower control module.
Why Dometic Refrigerator works on electric but not gas?
If your Dometic Refrigerator operates in electric mode but not in gas mode, several issues could be the cause. First, check if the mode or a switch is set incorrectly. The gas pressure might be too low or absent. Ensure the knob on the gas valve hasn't been turned to the off or closed position. Altitude might be affecting the refrigerator's operation in gas mode. The re-igniter might not be creating a spark, or the resistance on the gas valve solenoid might be out of specification. The orifice could be blocked or incorrectly sized. For older Americana models, the thermocouple might be defective. The burner could be blocked, the wiring might be faulty, shorted, or miswired, or there could be a short or a failed circuit in the lower control module.
Why is my Dometic DM2652 light on but not cooling?
If your Dometic Refrigerator isn't operating but the interior light is on, the issue might stem from a few potential causes. Check if the mode or a switch is set incorrectly. It's also possible that the DC voltage is too low or absent. The thermistor might not be operating within the proper temperature range. Another potential cause is that the communication wire harness has lost continuity or is shorted to ground. Lastly, there might be a short or a failed circuit in the lower control module.
| Type | Absorption Refrigerator |
|---|---|
| Color | Black |
| Total Capacity | 6 cu. ft. |
| Power Source | AC, DC, LP Gas |
| Total Storage Volume | 6 cu. ft. |
| Depth | 420 mm |
| Refrigerant | Ammonia |
| Climate Class | Tropical |
Details the safety alert symbol and its purpose in hazard identification.
Lists critical safety warnings related to carbon monoxide, electrical hazards, and pressure.
Diagnoses issues when the refrigerator is not operating and the interior light is off.
Troubleshoots operation failures when switching between electric and gas modes.
Identifies causes for insufficient cooling performance in any operating mode.
Guides diagnosis of system errors using fault descriptions and recommended actions.
Loading...