EN
FreshWell3000 Installation
11
The ventilation pipes (3) are joined by pressing them together thanks to the tapered
hole on the air outlet.
The pipes are connected to the register output.
To achieve the best efficiency it is recommended to:
lay the air pipes as short and straight as possible
restrict the length of the pipes to 5 m
don‘t lay the pipes near any heat sources
The recirculation air is drawn in through a grille or through other openings with a total
cross-section of at least 300 cm². The recirculation air opening (2) must be created
near the machine. If this is not possible, make sure that the air flow must be
obstructed by anything; if necessary, create an air duct between the opening and the
machine.
I
The recirculation air must be taken from inside the passenger compartment; if taken
from the outside then the efficiency of the under-bench air conditioner will be
reduced.
NOTE
To avoid condensation on the pipes insulate the pipes with insulation
material (not included in the scope of delivery).
FreshWell3000-I-16s.book Seite 11 Mittwoch, 12. Dezember 2018 2:11 14

Table of Contents

Other manuals for Dometic FreshWell 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dometic FreshWell 3000 and is the answer not in the manual?

Dometic FreshWell 3000 Specifications

General IconGeneral
BrandDometic
ModelFreshWell 3000
CategoryAir Conditioner
LanguageEnglish

Related product manuals