EasyManuals Logo

Dometic NDM1062 Operating Instructions

Dometic NDM1062
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #13 background imageLoading...
Page #13 background image
13
MAINTENANCE & SERVICE
CLEANING THE BURNER
1. Turn off the refrigerator
2. Unplug the power cord from the 120 VAC out-
let. Disconnect the wires or shut off the 12 VDC
power supply to the refrigerator.
3. Turn off the manual shut off valve.
4. Remove cover from burner housing.
5. Clean the burner tube with a brush. Blow out the
burner with compressed air.
6. Verify that the burner jet slots are centered un-
der the ue tube.
FIRE HAZARD. Never use a wire or pin to clear
obstructions from the burner jet as damage
will occur. Do not attempt to adjust the burner
jet. Failure to obey this warning could cause
a re resulting in death or serious injury.
7. Be sure to check the burner ame for proper ap-
pearance. The ame should be clear blue over
the slots of the burner.
Clear Blue Color
Of Flame
8. Check the electrode for proper location and gap.
Adjustments may be made with needle nose pli-
ers if necessary.
Electrode
1/8" to 3/16"
(3-5 mm)
Burner Tube
9. Turn on the manual gas shut off valve.
10. Examine all ttings for leaks. Use a commercial
non-corrosive bubble solution.
11. Connect the 120 VAC power cord.
12. Reconnect/Turn on the 12 VDC power.
13. Check LP gas safety shutoff.
Slots Centered
Under Flue Tube
REFRIGERATOR REMOVAL / DIS-
POSAL
To be performed by a qualied service technician
only.
See Installation Instructions for refrigerator removal /
replacement procedure, and for recycle information.

Other manuals for Dometic NDM1062

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dometic NDM1062 and is the answer not in the manual?

Dometic NDM1062 Specifications

General IconGeneral
BrandDometic
ModelNDM1062
CategoryRefrigerator
LanguageEnglish

Related product manuals