13
MAINTENANCE & SERVICE
CLEANING THE BURNER
1. Turn off the refrigerator
2. Unplug the power cord from the 120 VAC out-
let. Disconnect the wires or shut off the 12 VDC
power supply to the refrigerator.
3. Turn off the manual shut off valve.
4. Remove cover from burner housing.
5. Clean the burner tube with a brush. Blow out the
burner with compressed air.
6. Verify that the burner jet slots are centered un-
der the ue tube.
FIRE HAZARD. Never use a wire or pin to clear
obstructions from the burner jet as damage
will occur. Do not attempt to adjust the burner
jet. Failure to obey this warning could cause
a re resulting in death or serious injury.
7. Be sure to check the burner ame for proper ap-
pearance. The ame should be clear blue over
the slots of the burner.
Clear Blue Color
Of Flame
8. Check the electrode for proper location and gap.
Adjustments may be made with needle nose pli-
ers if necessary.
Electrode
1/8" to 3/16"
(3-5 mm)
Burner Tube
9. Turn on the manual gas shut off valve.
10. Examine all ttings for leaks. Use a commercial
non-corrosive bubble solution.
11. Connect the 120 VAC power cord.
12. Reconnect/Turn on the 12 VDC power.
13. Check LP gas safety shutoff.
Slots Centered
Under Flue Tube
REFRIGERATOR REMOVAL / DIS-
POSAL
To be performed by a qualied service technician
only.
See Installation Instructions for refrigerator removal /