13
Installation
Fig. 19
Dometic recommends the A 1625 ventilation
and flue gas extraction system which has
been tested and approved for this purpose.
These ventilation grills provide the required
open cross-section of at least 250 cm².
4.3 Installing the ventilation
system
LS 100
Fig. 20
LS 200
Top ventilation grille
with flue
Lower
ventilation grille
4.3.1 Ventilation systems
Fig. 23
Seal the mounting frame
making it waterproof
(
does not apply for
mounting frames with
integral seal
).
1
Fig. 24
Insert frame and screw
into position
2
To install the ventilation grilles LS 200, cut two
rectangles (451mm x 156mm) in the outer
wall of the vehicle (
for position of the cuts,
s
see Fig. 16).
Fig. 25
Insert and lock ventilati-
on grille.
3
Fig. 26
Clip the insert for flue
gas duct in position (
only
for L100 upper ventilati-
on system kit
).
4
4.3.2 Installing LS 100/LS 200
LS 100