The gas connection to the appliance is effected by means of a suitable
coupling tube fitting L8, DIN 2353-ST, complying with EN 1949 (e. g. Ermeto).
26
Following proper installation, a testing for leakage and a flame test must be
carried out by *qualified personnel in compliance with EN 1949 .
A certificate of testing must be issued.
* qualified personnel
Qualified personnel are accredited experts who are able, by virtue of their training and knowled-
ge, to vouch for the correct implementation of the leakage test.
The refrigerator must be equipped with a gas cock
(C) in the supply line to allow the supply to be disconnected.
Such a cut-out device must be readily accessible to the user.
C
SW 14
SW 17
CAUTION
20 Nm
max
10 Nm
max
WARNING
The gas connection may only be carried out by a qualified personnel.
Gas pressure
Category I
3P(30)
I
3P(37)
I3P(50) I3+ I
3B/P(50)
I
3B/P(30)
mbar 30 37 50 28-37 30-37 50 30
BE
DK
DE
••
FI
FR
GR
••
IE
••
IS
IT
LU
••
NL
••
NO
AT
••
PT
••
SE
CH
••
ES
UK
••

Other manuals for Dometic RM 7271 L

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dometic RM 7271 L and is the answer not in the manual?

Dometic RM 7271 L Specifications

General IconGeneral
BrandDometic
ModelRM 7271 L
CategoryRefrigerator
LanguageEnglish

Related product manuals