OPERATING
INSTRUCTIONS
RM1350
CANADA
Dometic, LLC
48 Zatonski, Unit 3
Brantford, ON N3T 5L8
CANADA
Phone: 519-720-9578
USA
Dometic, LLC
Service Ofce
2320 Industrial Pkwy.
Elkhart, IN 46516
Phone: 574-294-2511
Corporate Ofce
2320 Industrial Parkway
Elkhart, IN 46516
For Service Center
Assistance
Call: 800-544-4881
FOR YOUR SAFETY
If you smell gas:
1. Open windows.
2. Don’t touch electrical switches.
3. Extinguish any open ame.
4. Immediately call your gas supplier.
PAR MESURE DE SÉCURITÉ
Si on détecte une odeur de gaz :
1. Ouvrir les fenêtres.
2. Ne pas toucher les commutateurs électri-
ques.
3. Éteindre toute amme nue.
4. Contacter immédiatement le fournisseur
de gaz.
FOR YOUR SAFETY
Do not store or use gasoline or other am-
mable vapors and liquids in the vicinity of
this or any other appliance.
PAR MESURE DE SÉCURITÉ
Ne pas entreposer ou utiliser de l’essence
ou autre vapeur ou liquide inammable au
voisinage de cet appareil ou de tout autre
appareil ménager.
Im p ro p er in s ta l la t io n , ad ju s tm e nt ,
alteration, service or maintenance can cause
injury or property damage. Refer to this man-
ual. For assistance or additional information
consult a qualied installer, service agency
or the gas supplier.
Une installation, un glage, une modication,
un dépannage ou un entretien, effectués in-
correctement, peuvent provoquer des blessu-
res ou des dommages matériels. Se reporter
à ce manuel. Pour obtenir une aide ou des
informations complémentaires consulter un
installateur qualié, une entreprise de dépan-
nage ou le fournisseur de gaz.
AVERTISSEMENT
!
If the refrigerator stops cooling - or - if
it emits an ammonia smell, immediately
turn the refrigerator off and contact a
Service Center.
Si le réfrigérateur cesse de refroidir - ou s’il
s’en dégage une odeur d’ammoniac, arrêter
immédiatement le réfrigérateur et contacter
un centre de service après-vente.
AVERTISSEMENT
!
REVISION
Form No. 3313352.019 6/11
(Replaces 3313352.000)
(French 3313353.017)
©2011 Dometic, LLC
LaGrange, IN 46761

Other manuals for Dometic RM1350

Questions and Answers

  • B
    bowersterriAug 19, 2025
    What to do if Dometic RM1350 Refrigerator is not cold enough?
    • C
      Christopher McgeeAug 19, 2025
      If your Dometic refrigerator or freezer isn't cold enough, try these steps: * Check and adjust the thermostat if needed. * Ensure there isn't a power failure. * Make sure the refrigerator is level, as absorption refrigerators need to be level to function correctly. * Check the door gasket to ensure the door is closing properly. * Avoid heavy frost build-up by not leaving the door open longer than necessary. * Don't overpack the refrigerator; arrange food to allow for free air circulation to prevent the unit from working harder.
  • K
    Kristin SuarezAug 21, 2025
    Why my Dometic Refrigerator does not work on electric?
    • L
      Lisa BullockAug 21, 2025
      If your Dometic refrigerator isn't working on electric, check these potential causes: * Ensure the plug is firmly connected to the receptacle and that the receptacle is energized by plugging in another appliance. * Verify there isn't a power failure. * If these steps don't resolve the issue, the fuse may be blown, and you should turn the refrigerator off and contact a Dometic dealer or Service Center for repair.
  • M
    Michael CarterAug 23, 2025
    What to do if Dometic RM1350 Refrigerator does not work in gas operation mode?
    • S
      sabrinamorrowAug 25, 2025
      If your Dometic refrigerator isn't working in gas operation mode: * Check if the LP gas bottle is empty and change it if needed. * Remove air from the gas pipe by repeating the ignition sequence. * If the problem persists, turn the refrigerator off and contact a Dometic dealer or Service Center for repair.
  • M
    Michelle GrayAug 26, 2025
    How to fix flashing LP message on Dometic Refrigerator?
    • C
      Courtney DiazAug 26, 2025
      If the message alternates between “LP” and the fresh food compartment temperature, it indicates that the LP gas ignition failed. Here's what you can do: * Turn the refrigerator OFF and then back ON to return to normal operation. * If there is air in the gas line, you may have to repeat the lighting procedure (45 seconds) by turning the refrigerator off and on several times in order to purge the air out of the gas lines. * Ensure the LP gas bottle is not empty and replace if needed. * If there is an obstruction in or on the burner or burner jet, or the burner jet is clogged, turn the refrigerator off and contact a Dometic dealer or Service Center for repair.
  • J
    John FreemanAug 28, 2025
    Why is my Dometic RM1350 not cold enough?
    • D
      Dr. Samuel HartAug 28, 2025
      If your Dometic Refrigerator isn't cold enough, several factors could be the cause. First, check the thermostat and adjust it if needed. Also, check for a power failure or if the overheating protection has been triggered. Ensure the refrigerator is level and the door is closing properly by checking the door gasket. Heavy frost build-up on evaporator fins can also affect cooling, so avoid leaving the door open longer than necessary to prevent this. Finally, an overpacked refrigerator can strain the unit, so arrange food to allow for free air circulation.
  • W
    webbandreaAug 30, 2025
    What to do if Dometic Refrigerator emits an ammonia smell?
    • M
      maria25Aug 30, 2025
      If your Dometic refrigerator emits an ammonia smell: * Immediately turn the refrigerator off at the front control panel. * Do NOT open refrigerator doors. * Open coach windows and door to air out the coach and evacuate. * Turn off manual LP gas valve at the rear of the refrigerator. * Disconnect the 120 VAC power at the rear of the refrigerator. * Contact a Dometic dealer or Service Center for repair and do not use the refrigerator until it has been repaired.
  • M
    Megan SullivanSep 2, 2025
    What to do if Dometic RM1350 stops cooling?
    • K
      Kevin ZavalaSep 2, 2025
      If your Dometic refrigerator stops cooling, immediately turn it off and contact a Dometic dealer or Service Center. Do not leave it running for an extended period, and never try to solve the problem by repeatedly restarting the refrigerator. Do not use the refrigerator until it has been repaired.
  • L
    Luke DeanSep 4, 2025
    What to do if Dometic RM1350 does not work on 120V AC?
    • K
      Kyle HoustonSep 4, 2025
      If your Dometic Refrigerator isn't working on 120V AC, make sure the plug is firmly connected to the receptacle and that the socket is switched on. Test the receptacle by plugging in another appliance. Also, check the fuses for the AC supply and control system to ensure they are intact.
  • D
    Daniel KruegerSep 6, 2025
    Why Dometic Refrigerator does not work in gas operation mode?
    • W
      William DavisSep 6, 2025
      If your Dometic Refrigerator isn't working in gas operation mode, start by checking if the gas bottle is empty and change it if necessary. If the bottle is not empty, there may be air in the gas pipe. Also, ensure the LP gas pressure is not low at the burner; set the main regulator to maintain pressure above 11 inches water column at the pressure tap.
  • L
    logancrawfordSep 8, 2025
    What to do if Dometic RM1350 Refrigerator has stopped cooling?
    • A
      Angela WilsonSep 9, 2025
      If your Dometic Refrigerator has stopped cooling, immediately turn it off and consult a Dometic dealer.

Summary

Safety Precautions

Gas Leak Procedures

Steps to follow if a gas leak is detected.

Flammable Vapors Warning

Precaution against storing flammable liquids nearby.

Installation and Service Hazards

Dangers from improper installation, adjustment, or service.

Ammonia Leak and Cooling Failure

Actions for cooling failure or ammonia smell.

Refrigerator Overview and Features

Control Panel Functions

Explanation of control panel buttons and display indicators.

Refrigerator Leveling Importance

Critical need for proper leveling for absorption refrigerators.

Instructions for Use

Starting the Refrigerator

Step-by-step guide to starting the refrigerator.

Ice Maker Operation Requirements

Conditions for ice maker to function correctly.

Storage Compartments

Fresh Food Storage Guidelines

Guidelines for storing fresh food effectively.

Product Care and Maintenance

Defrosting the Refrigerator

Step-by-step instructions for defrosting the refrigerator.

Replacing Refrigerator Fuses

Instructions for replacing the refrigerator's fuses.

LP Gas Connection Inspection

Procedure for checking LP gas connections for leaks.

Burner Cleaning and Flame Inspection

Steps for cleaning and inspecting the LP gas burner assembly.

Refrigerator Removal and Installation

Troubleshooting Guide

Common Symptom Resolution Table

Table of common symptoms and their solutions.

Error Code Explanations and Actions

Explanation of error codes displayed by the refrigerator.

Dometic RM1350 Specifications

General IconGeneral
BrandDometic
ModelRM1350
CategoryRefrigerator
LanguageEnglish

Related product manuals