EasyManua.ls Logo

Dometic RM3762 - Troubleshooting Error Codes; Error Code Explanations and Solutions

Dometic RM3762
22 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
13
TROUBLESHOOTING
ERROR CODES
For information about error codes, refer to the following table. The codes are displayed ashing (alternating between tem-
perature and message). If an error code is displayed, contact a Dometic dealer or Service Center.
After having solved the problem, turn refrigerator OFF and then back ON. The refrigerator will return to normal operation.
ERROR CODES INFORMATION
E0 No communication between display and power module.
E1
Disconnected LP gas valve or hardware fault in the LP gas operation system. The refrigerator
may still be operational on 120 VAC.
E2
A failure of the temperature sensor device or associated electronic circuitry has occurred. Make
sure the sensor wire is connected.
E3 The cooling unit has malfunctioned. Contact a Service Center.
E4 DC voltage is out of range (exceeds or drops below the limit values, approximately 8-18 VDC).

Other manuals for Dometic RM3762