REMOVAL OF FLUE GASES
The ventilation passage at the rear of the recess, between
the outer wall of the vehicle and the refrigerator must be
sealed off against the living space, so cold draughts are
excluded (winter camping) and no ue gases can pene-
trate into the living space of the vehicle.
The ue gases can be dispersed from the ventilation
passage using one of the OPTIONAL Dometic ventila-
tion systems. The top, bottom and sides of the ventila-
tion passage should be insulated to prevent condensation
and cold draughts. The ventilation passage walls must be
constructed of a non combustible material.
VENTILATION HEIGHTS
MINIMUM VENTILATION HEIGHTS IN MM
Installation with upper
and lower side vent
Installation with roof vent
and lower side vent
1417 1577
At extreme ambient temperatures the refrig-
eration unit will only perform adequately when
properly ventilated.
Fig. 2
Minimum
ventilation
height
Minimum
ventilation
height
Option twoOption one
RM4601 1417 mm
Warm air deecting plate
RM4601 1577 mm
CLEARANCES
Minimum clearances (mm) to combustible materials
(Fig. 3 & Fig. 4)
G Top 0
K Side 0
L Bottom 0
M
1
Rear 0
1
The distance between the rearmost part of the refrigerator and the wall
behind the refrigerator.
Fig. 4
M M
Warm air deecting plate
G
K
Fig. 3
TECHNICAL DATA
Overall dimensions, refrigerator
Height (incl. controls) .............1427 mm
Width ..........................632 mm
Depth (incl. handle) ...............668 mm
Recess dimensions
Height. . . . . . . . . . . . . . . . . . . . . . . . . 1415 mm
Width ..........................607 mm
Depth ..........................620 mm
Capacity
Gross .........................186 litres
Net ...........................171 litres
Frozen food compartment ..........47 litres
Weight (without packaging) .......... 61.5 kg
Electrical data
Input 230-240 volt .............. 325 watt
12 volt ............. 275 watt
Energy consumption (in 24h) ....... 4.6 kWh
LP gas data
Input, max ..................... 1.7 MJ/h
Energy consumption (in 24h) ..........440 g
Cooling medium: Ammonia
Sodium chromate is used for corrosion protection (less than
2 weight % of the coolant).
For alternate ventilation heights and vent congurations