APPENDIX C - WORKING INSTRUCTIONS FOR THE GAS SAFETY SYSTEM
WORKING DIAGRAM
TECHNICAL SPECIFICATIONS
Classication codes according to EN298 A-M-R-V-X-K
Class of protection according to Low Voltage Directive IP-20
Waiting time / TW 8 s
Safety time / TS 45 s
Inter-waiting time / TWI 120 s
Working temperature –20°C to +45°C
Nominal working voltage* 12 - 13,8V DC
Resistance to vibration according to EN60068-2-6:1995
*Functional approved at a voltage variation of +20% through –25%
Thermostat
Spark
Gas valve
Flame detector device
Lock out indication
TW TS TS TWI TS TWI TS