Operating the generator TEC30D EV
20
OIL TEMP PRESS
Engine temperature too
high.
The generator stops. Switch off the generator and
leave it to cool down. Check
that the ventilation openings
are not obstructed.
If the problem persists,
contact the manufacturer's
branch office in your country
(addresses on the manual‘s
back page).
GENERATOR ALERT!
General alarm message
The generator stops. Check the system by refer-
ring to the troubleshooting
table (page 27).
If the problem persists,
contact the manufacturer's
branch office in your country
(addresses on the manual‘s
back page).
OVERLOAD!
The consumers generate an
overload at the output.
The inverter switches off,
therefore no voltage is
supplied but the engine
carries on running until it
goes off.
Reduce the connected load.
Stop the generator and
restart it.
SHORT CIRCUIT
The consumers cause a short
circuit at the output.
The inverter switches off,
therefore no voltage is sup-
plied but the engine carries
on running until it goes off.
Check the connected
consumers. Stop the
generator and restart it.
OVER TEMPERATURE
Overheating
The inverter switches off so
no voltage is supplied to
cool the generator, but the
engine carries on running.
Leave the engine to cool
down for a few minutes. Stop
the generator and restart it.
LOW POWER ENGINE
The inverter supply voltage
has dropped.
The generator stops. Reduce the connected load
and start the generator
again.
RESTART GEN?
Message appears after the
generator has stopped due
to overheating.
The generator is switched
off.
Press the start button to
restart the generator.
Display message
Description
Generator behaviour Measures