ELECTRICAL CONNECTIONS 1,5 AND 2,2 KW
Port Function Description
1 PE
AC 220/240 V, input2 L
3 N
4 Braking resistor, output+
5 Braking resistor, input -
6 Motor brake +
DC 24 V
7 Motor brake -
8 Reserved
9 Safety device, input 1 NO (anti-jamming sensor, safety edge, PHOTOCELL-N)
10 Safety device, input 2 NO photocells (when closing, reverse movement to open limit)
11 Com/Gnd
12 DC 24 В +
13* Automatic opening, input NO (radar, sensor, magnetic loop, DHRE-1, etc.)
14 Partial opening, input NO (radar, sensor, button)
15** Start, input NO (radar, sensor, button, DHRE-1)
16 Com/Gnd
17 Opening limit NO (limit sensor)
18 Closing limit NO (limit sensor)
19 Lock NO (blocking of door opening)
20 Com/Gnd
21 DC 24 В +
22 Output 1A
Disable by default, change the value of Output 1 Config and 1A-1B will change to
the desired value
23 Output 1B
24 Output 2A
Disable by default, change the value of Output 2 Config and 2A-2B will change to
the desired value
25 Output 2B
26 Output 3A
Disable by default, change the value of Output 3 Config and 3A-3B will change to
the desired value
27 Output 3B
28 Output 4A
Disable by default, change the value of Output 4 Config and 4A-4B will change to
the desired value
29 Output 4B
30 RS485 +
31 RS485 -
32 Com/Gnd
33 Manual opening, input NO
34 Manual opening, input NO
35 Manual stop, input NO
36 Emergency stop, input NC
5. ELECTRICAL CONNECTIONS 1,5 AND 2,2 KW
Table 12. Description of ports' functions of 1,5 and 2,2 kW control units (part no. PE500(C) and PE700B(C) respectively)
* This port is active only in automatic mode.
**This port opens the door when it's closed and closes if it's open.
WARNING!
Before performing any electrical connections, ensure power supply is DISCONNECTED to avoid serious injury or
death!
When connecting several safety devices to input 1, the control contacts must be connected in parallel and be NO.
Set the input 2 in NC. To do this, follow these steps: set — 6668 > advanced settings > contact type > safety2 >
NC/NO. For more information, see section 6.5 of this manual.