6004-065-X-2-21
11
Mounting Bracket and Gate Attachment Bracket
Operator Mounting Positions
Attach mounting bracket to pilaster or wall with four (4) #10
screws and suitable expansion hardware (Not supplied).
See next page for specific layout dimensions and page 2 for mounting bracket dimensions.
See next page for specific layout dimensions
and page 2 for operator dimensions.
Mounting Bracket shown in
Left-Side Opening Position.
1 5/8”
MUST be level!
Weld gate attachment bracket to gate or
use two (2) suitable screws (Not supplied).
DOORKING
DOORKING
DOORKING
A support bar must be used if the operator is mounted
in the middle of the gate and typically spans 4 or 5
pickets. The pickets will bend if not supported.
Top
Middle
Bottom
Left-Side Position Right-Side Position
Support Bar
Extreme force will be exerted on
these brackets during gate cycling.
Bottom Installation Note: Make sure that the
operator is mounted high enough off the
ground that it will NOT come in contact with
standing or flowing water. This will damage
the operator.