Operation Section
99
Starting the Engine
Prestart Conditions
NOTE: The engine will not start unless the
transmission directional control lever is in
the NEUTRAL position.
Mechanical Parking Brake (If Installed)
Typical Example
Electronic Parking Brake (If Installed)
Typical Example
1. Engage the parking brake, if not already
engaged.
2. Place the transmission directional control lever
in NEUTRAL position.
NOTICE
When you restart the engine after turning off it, wait
4 to 5 seconds and restart it to protect the starter.
Diesel Engine
Starting Diesel Engine at cold
1. Turn the ignition key to the ON position. The
start preheat light will come ON. The preheat
light will stay ON maximum 20 seconds,
depending on the ambient air temperature.
NOTICE
Do not crank more than 10 seconds continuously.
If engine coolant is cold, engine low idle speed could
be higher than normal condition. (Electronic Engine)
2. After the preheat light goes OFF, turn the
ignition key to the START position.
3. Release the ignition key after engine starting
and check the engine condition.
4. If the engine stalls or does not start, turn the
ignition key to the OFF position, then repeat
steps 1 thru 3.
Starting Diesel Engine at Warm (Mechanical
engine)
1. Turn the ignition key to the ON position and then
to START position, without waiting for the
preheat light to go OFF. At the same time fully
depress the accelerator.
2. Release the ignition key when the engine starts
and release the accelerator pedal to a low idle
position.
Release the ignition key after engine starting
and check the engine conditions.
LP Engine
WARNING
LP fuel is flammable and can cause personal
injury. Inspect LP fuel lines and fitting for leaks.
Inspect tank for secure mounting.