Operation Section
125
DEF/Ad-Blue Quality Failure for Europe
Inducement
Stage
Condition
Repeat
Offence
(within
40hrs)
Inducement Strategy
DEF Level
Indicator
DEF
Indicator
Engine
Check
Lamp
Buzzer
Torque
Reduction
RPM
Limit
Normal NA
≥ 90%
of
counter
value
for
severe
induce
ment
(20hr)
Green ON Off Off Off 0% NA
Level1
Poor DEF
quality
was
detected
Green ON On Off Off 0% NA
Level2
10~20hrs Green ON On On
At starting
& Every
20min
25% NA
Level3
over
20hrs
Green ON Blinking Blinking
Every
10min
50%
60%
(about
1500rpm)
Inducement
Stage
Condition
Repeat
Offence
(within 40hrs)
LCD Display
Method Message on the Display
Normal NA
≥ 90% of
counter
value for
severe
inducement
(20hr)
NA NA
Level1
Poor DEF quality
was detected
For 1min
At starting & Every 20min
DEF QUALITY POOR -
CHANGE NOW
Engine Power will be
Reduced
Level2
10~20hrs
For 1min
At starting & Every 10min
DEF QUALITY POOR -
CHANGE NOW
Engine Power Reduced By
25%
Level3
over 20hrs Continuous
DEF QUALITY POOR -
CHANGE NOW
Engine Power Reduced By
50%

Table of Contents