Operation Section
128
Impeded EGR / Interruption of Dosing for Europe only
There are several interruption level points at which the DEF indicator and engine check lamps light up or blink
and the display shows a message to warn that the DEF/Ad-Blue is not being consumed due to a fault on the
engine EGR valve and SCR system. The lower the point, the more the system limits the engine power and
speed. As shown in the table below, for your information, we provide correlation of Impeded EGR /
Interruption of Dosing inducement strategy and LCD display.
Impeded EGR for Europe
Inducement
Stage
Condition
Repeat
Offence
(within
40hrs)
Inducement Strategy
DEF Level
Indicator
DEF
Indicator
Engine
Check
Lamp
Buzzer
Torque
Reduction
RPM
Limit
Normal NA
≥ 95%
of
counter
value
for
severe
induce
ment
(100hrs)
Green ON Off Off Off 0% NA
Level1
Impeded
EGR
detected
Green ON On Off Off 0% NA
Level2
36~100hr
s
Green ON On On
At starting
& Every
20min
25% NA
Level3
over
100hrs
Green ON Blinking Blinking
Every
10min
50%
60%
(about
1500rpm)
Inducement
Stage
Condition
Repeat
Offence
(within 40hrs)
LCD Display
Method Message on the Display
Normal NA
≥ 95% of
counter
value for
severe
inducement
(100hrs)
NA NA
Level1
Impeded EGR
detected
At starting & Every 20min
SCR SYSTEM MALFUNCTION
CALL DOOSAN SERVICE AGENT
Engine Power will be Reduced
Level2 36~100hrs Every 10min
SCR SYSTEM MALFUNCTION
CALL DOOSAN SERVICE AGENT
Engine Power is Reduced By 25%
Level3
over 100hrs Continuous
SCR SYSTEM MALFUNCTION
CALL DOOSAN SERVICE AGENT
Engine Power is Reduced By 50%