Section 6 Installation
6.1 Installation Warnings
DANGER: Do not install the console in a hazardous area!
Flammable fumes can cause an explosion when mixed with air.
Dangerous areas can occur where there are gases or fumes.
The MagLink LX4 console is NOT explosion-proof.
WARNING: Only use fuses of 250 V - 1 A for input power.
WARNING: connect the Intrinsically Safe Ground connection of the console
to the earth system of the site. A possible explosion or fire can occur if
damage is caused to the intrinsic safety of the device and high voltages are
sent to the Hazardous Area.
6.2 Installation Location
Select a location for the console installation where weather cannot cause negative effects or damage to the
electrical circuits (high and low temperatures, high humidity, direct sunlight etc.).
NOTICE: Install the console in a place that is protected from moisture, direct sun, and
water splashes. The console should be installed indoors in a climate-controlled room.
CAUTION: The console must be installed in a safe area.
M2050 MagLink LX 4 Installation Manual | Dover Fueling Solutions 14