EasyManua.ls Logo

Doyon DRIP1TLO - Distances to Respect; Installation

Doyon DRIP1TLO
47 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
A4
DISTANCES TO RESPECT
Top of the proofer: a clearance of 24 to 36 inches to the ceiling must exist to permit
maintenance.
Back and sides: 4 inches.
I N S T A L L A T I O N
IN GENERAL
Take off the packaging material with care. Take off all the material used for packing and accessories.
Each unit is set up to be used with the electrical supply specified on the nameplate fixed on the front
of the unit.
1. To the electrician
Electrical supply installation must be in accordance with the electrical rating on the nameplate.
WARNING
The electrician must make sure that the supply cable does not come in contact
with the oven top which becomes hot.
2. To the plumber
This equipment is to be installed to comply with the applicable federal, state, or local plumbing
codes.
Connect the steam system (1/4 NPT) to the water distribution network.
We highly recommend to use a water softener to eliminate minerals in the water. We suggest you to
use CUNO # CFS6135 (Doyon part number PLF240).
WARNING
Do not adjust the needle valves, it has been done at the factory.