1)
If the flow rate for a single sample taking measurement is additionally adjusted,
then the tolerance is equal to the tolerance of the used flow meter. E. g. if the
used flow meter has a tolerance of ± 3 %, then the adjusted flow rate of the
Dräger X-act 5000 has a tolerance of ± 3 %.
9 Order list
Power supply
Battery capacity Tube:
>1000 strokes at 25 °C (77 °F)
Sampling:
up to 12 hours at 25 °C (77 °F)
depending on adjusted flow rate
Rechargeable battery
(NiMH Battery)
7.2 V, 1500 mAh
Charging current: 400 mA,
max. charging voltage: 15 V
Charging time: <4 hours
Alkaline battery pack See Section 9 for approved battery
types
Short-term measurements Adjustable,
1 to 200 strokes
depending on the used tube
Stroke volume: 100 mL ± 5 mL
Sample taking Sampling time
adjustable, up to 12 hours
depending on the adjusted flow rate
Resolution:
in steps of 15 minutes (default setting)
in steps of 1 minute
(can be set in the password-protected
menu)
Flow rate range 0.1 to 2.0 L/min
Flow rate Resolution Tolerance
0.1 to 1.0 L/min 0.1 L/min ±10 %
1)
1.0 to 2.0 L/min 0.2 L/min ±10 %
1)
Description and designation Order number
Dräger X-act 5000
without power supply; shoulder strap included
45 23 500
Power supply
Rechargeable battery NiMH, T4 45 23 520
Alkaline battery pack, T4, without batteries
(6 batteries are needed)
45 23 525
Alkaline battery (pack of 6) 81 03 594
Charging accessories
Wall mount charger 110 – 240 VAC
for charging 1 NiMH battery pack
45 23 545
In-cab charger 12/24 V 45 23 511
Accessories
SO
3
filter 81 03 525
Shoulder strap 45 23 565