Installation instructions
Technical Data
Setting Range
50° 80°C
Differential
8°C approx.
Switch rating
3 (1) A 230V ac
Switch type
SPDT
Earth
Double insulated
not required
Connections
C common
1 call
2 satised
Fixing
Plastic-coated spring wire
with hook and eyelet.
Conforms to the essential
requirements of the following directives:
2004/108/EC Electromagnetic compat ibility
Directive
2006/95/EC Low Voltage Directive
Cylinder thermostats
Make Model Common Call Satised
HTS 3 C 1 2
Lifestyle HTS 2 R B Y
Danfoss
Randall
AT (CN4) 1 2 3
Drayton CS 1/CS 2 1 2 3
Honeywell L641A C 1 2
Landis
& Gyr
RAM 1 1 2 3
Potterton
Myson
PTT 1 L H C
Sunvic 1452/
SA2451
3 1 2
Sopac SAY C 1 2
Smiths SCT 1 1 2 3
Tower CS 1 R B Y
Barlo CT 1 R B Y
Pollution Degree
2
Ball pressure
Test Temperature
110ºC
Rated impulse
voltage
2.5kV
2011/65/EU – Restriction of the Use of Certain
Hazardous Substances (RoHS)
Energy Class
I = 1% (Acc. EU
811/2013, 812/2013,
813/2013, 814/2013)
Question and Answer IconNeed help?

Do you have a question about the Drayton HTS3 and is the answer not in the manual?

Drayton HTS3 Specifications

General IconGeneral
ConnectivityWired
MountingWall-Mounted
Temperature Range5°C to 30°C
Voltage230V AC
Switching Capacity750W
Accuracy±0.5°C
DisplayLCD
Switching Current3A

Summary

Technical Data

Cylinder thermostat comparison

HTS3 Installation Guide

Positioning the HTS3

Install the HTS3 cylinder thermostat approximately one third of the way up the hot water cylinder at the front.

Wiring Connections

Connect the HTS3 using sufficient 3-core cable to the installation position without tension. Ensure double insulation.

Fixing to the Cylinder

Hold the HTS3 base in good contact with the cylinder metal using a cut spring fixing cable with hook and eyelet.

Commissioning and Setting

Setting the Temperature

Position the setting arrow at the desired nominal hot water temperature, or fully anticlockwise for OFF.