090-728 ISSD
HTS3 Cylinder
Thermostat
Installation instructions
Technical Data
Setting Range
50° – 80°C
Differential
8°C approx.
Switch rating
3 (1) A 230V ac
Switch type
SPDT
Earth
Double insulated
– not required
Connections
C – common
1 – call
2 – satisfied
Fixing
Plastic-coated spring wire
with hook and eyelet.
Conforms to the essential
requirements of the following directives:
2004/108/EC – Electromagnetic compat ibility
Directive
2006/95/EC – Low Voltage Directive
Cylinder thermostats
Make Model Common Call Satisfied
HTS 3 C 1 2
Lifestyle HTS 2 R B Y
Danfoss
Randall
AT (CN4) 1 2 3
Drayton CS 1/CS 2 1 2 3
Honeywell L641A C 1 2
Landis
& Gyr
RAM 1 1 2 3
Potterton
Myson
PTT 1 L H C
Sunvic 1452/
SA2451
3 1 2
Sopac SAY C 1 2
Smiths SCT 1 1 2 3
Tower CS 1 R B Y
Barlo CT 1 R B Y
Pollution Degree
2
Ball pressure
Test Temperature
110ºC
Rated impulse
voltage
2.5kV
2011/65/EU – Restriction of the Use of Certain
Hazardous Substances (RoHS)
Energy Class
I = 1% (Acc. EU
811/2013, 812/2013,
813/2013, 814/2013)