manual patient lift
item # 13023
www.drivemedical.com
lifetime limited
warranty
Your Drive brand product is warranted to be free
of defects in materials and workmanship for the
lifetime of the original consumer purchaser.
This device was built to exacting standards and
carefully inspected prior to shipment. This Lifetime
Limited Warranty is an expression of our confi-
dence in the materials and workmanship of our
products and our assurance to the consumer of
years of dependable service.
In the event of a defect covered by this
warranty, we will, at our option, repair or replace
the device.
This warranty does not cover device failure
due to owner misuse or negligence, or normal
wear and tear. The warranty does not extend to
non-durable components, such as rubber
accessories, casters, and grips, which are subject
to normal wear and need periodic replacement.
If you have a question about your Drive device or
this warranty, please contact an authorized Drive
dealer.
© 2005 Medical Depot, Inc. All rights reserved.
Drive is a trademark of Medical Depot, Inc.
Port Washington N.Y. 11050 USA Made in China
Question and Answer IconNeed help?

Do you have a question about the Drive 13023 and is the answer not in the manual?

Drive 13023 Specifications

General IconGeneral
BrandDrive
Model13023
CategoryLifting Systems
LanguageEnglish

Summary

Lifetime Limited Warranty

Patient Lift Instructions

Swivel Bar (E)

Component used to attach the sling for patient support during lift.

Mast (C)

Includes steering handles; supported in the base socket and secured by a screw.

Pump Assembly (F)

Features pump handle and control valve for raising/lowering the boom.

Shifter Handle (B)

Used to open and close the base legs for stability and storage.

Patient Lift Maintenance & Care

Pre-Use Checks

Inspect base, wheels, locks, mast, boom, hanger post, and sling attachments for wear before each use.

Three-Month Checks

Check swivel bar hook, eye hook, nylon washers, and piston seals every three months.

Three-Month Lubrication

Lubricate mast, actuator mounting, base plate, and wheel bearings with grease every three months.

Cleaning Procedure

Clean lift with mild soap, dry thoroughly, apply wax, protect painted surface from oil.

Patient Lift Maintenance & Care Continued

Hydraulic Pump Operation

Instructions on pump use, common boom lowering, and reporting faulty pumps.

Sling Safety and Care

Warnings against bleach use and checks for sling damage to ensure patient safety.