Do you have a question about the DRYDEN AQUA DA-GEN and is the answer not in the manual?
Brand | DRYDEN AQUA |
---|---|
Model | DA-GEN |
Category | Inverter |
Language | English |
Details the physical components and connections on the DA-GEN control panel.
Description of the DA-GEN cell, a key part of the water treatment system.
Overview of the main display screen elements including temperature, intensity, and status indicators.
Explanation of the functionality for each navigation key (PLUS, MINUS, OK, UP, DOWN, RETURN/ESCAPE).
Information regarding the indicator for the light function on the main screen.
Details on installing external controllers, filter components, probes, and ancillary devices.
Information on the electrical power consumption for different DA-GEN models.
Diagrams and instructions for connecting probes, pumps, relays, and communication modules.
Steps for adjusting water parameters like alkalinity, pH, and chlorine levels.
Guidance on adding magnesium chloride or normal salt to the pool water.
Configuration options for language, time, display brightness, sound, password, and system info.
Explanation of the paddle flow switch's role in stopping hydrolysis during no-water flow.
Instructions for connecting the suction lance for the pH bottle.
Details on setting up hydrolysis functions, disinfection production, and mode selection.
Adjusting setpoints for pH, redox, chlorine, and conductivity measurements.
Steps for calibrating the pH probe using buffer solutions or manual adjustment.
Steps for calibrating the redox probe using buffer solutions or manual adjustment.
Steps for calibrating the free chlorine probe using buffer solutions or manual adjustment.
Detailed steps for calibrating the redox probe, including manual adjustments.
Detailed steps for calibrating the conductivity probe, including manual adjustments.
Information on installing and configuring variable speed pumps.
Setting filtration modes, states, and speeds for variable speed pumps.
Configuring filter cleaning cycles and backwash operations.
Operating the filtration system in manual mode.
Setting up and operating the filtration system in automatic mode with timers.
Configuring automatic backwash operations using the Besgo valve.
Overview of lighting control options, modes, and states.
Operating the pool lights manually via the control panel.
Automating pool lighting based on timer settings.
Configuration options for LED spotlights, including color and pulse length.
Steps for connecting the DA-GEN to a WiFi network, including scanning and password entry.
Selecting available WiFi networks and manually entering network names and passwords.
Checking the status of the WiFi connection and performing connection tests.
Information on how pool cover status affects filtration speed and system operation.
Overview and configuration of auxiliary relays for external devices like dosing pumps.
Operating auxiliary relays manually or automatically based on timers.
Programming relay activation times for specific functions.
Customizing the names of auxiliary relays to match their assigned functions.
Performing regular checks on salt concentration and visual inspection of the hydrolysis cell.
Detailed instructions for cleaning the hydrolysis cell using acid or vinegar.
Routine pool maintenance including vacuuming, filter backwashing, and probe care.
Solutions for common problems like blank display, excess chlorine, and setpoint issues.
Diagnosing and resolving problems related to incrusted cells and low free chlorine levels.
Troubleshooting alarm AL3 and situations where the dosing pump stops unexpectedly.
Resolving polarity intensity imbalances and dosing pump operational errors.
Key safety warnings, chemical handling advice, and system adaptation period information.
Wiring diagrams for probes and sensors connecting to the DA-GEN unit.
Wiring diagrams for filter pumps, auxiliary relays, and lighting controls.
Wiring for filtration control, variable speed pumps, and device communication.
Wiring diagrams for external displays and WiFi modules.
Steps to access the service menu, including password entry.
Guidance on navigating through the system settings within the service menu.
Configuration of installer-defined relay functions and predefined relay assignments.
Configuring parameters related to external devices like flow mode and hydrolysis settings.
Adjusting hydrolysis mode, polarity times, and dead time settings.
Configuring pH setpoint modes and temperature display/control settings.
Settings for controlling the heating system via temperature probes.
Selecting the type of pump connected to the system (standard or variable speed).
Configuring settings for Variable Speed Pump A and B, including speed settings.
Configuring pH dosing pump modes, other pumps, and handling alarm AL3.
Defining system behavior based on tank level signals for pH or chlorine.
Configuring extra settings for gas sensors, flow switches, and paddle delays.
Information on resetting working hour counters for components.
Setting the node address for configuring multiple user interfaces.
Configuring server and port settings for WiFi module connectivity.
Wiring schematics for DA-GEN with Speck Badu Profi / Eco VS pumps.
Wiring schematics for DA-GEN with Speck Badu Eco Motion pumps.
Wiring diagram for DA-GEN with Pentair Intelliconnect / Intelliflo pumps.
Wiring diagram for DA-GEN with Sta-Rite VS S5P2R / S5P1R pumps.
Wiring diagram for DA-GEN with Schneider ATV 212 drives.
Wiring diagram for DA-GEN with Invertec Optidrive E2 drives.
Information on CE marking and relevant EU directives applicable to the DA-GEN.
List of applicable standards and norms for product testing and measurement.
Details of the European guarantee terms and conditions in Spanish.
Details of the European guarantee terms and conditions in English.
Details of the European guarantee terms and conditions in German.
Details of the European guarantee terms and conditions in French.