3. SYSTEM INSTALLATION
* Filtration control by external timer
Filtration mode:
“Manual/ON”
230 V
* Filtration control by internal timer
Filtration mode:
Automatic
see Chapter 12
230 VLINKS TO FILTER PUMP
Paddle ow switch and temperature module
APF
®
dosing pump
pH dosing pump
pH injection
Prelter
Wi module
APF
®
(not included)
pH-Minus
(not included)
If Outdoor pool: ACO
®
(not included)
Besgo valve (not included)
External pump controller*
Filter with AFM
®
Filter pump
Control Panel
Free chlorine cell with rotameter
Cell
(always in vertical position if installed without paddle
ow switch )
pH probe
Redox probe and/or conductivity probe
Product
Maximum
consumption
DA-GEN 24 90 W
DA-GEN 45 125 W
DA-GEN 90 180 W
DA-GEN 150
175 W
Private
Product
Maximum
consumption
DA-GEN 240
680 W
DA-GEN 360
1000 W
DA-GEN 500
1020 W
DA-GEN 750
2880 W
Public
Electrical consumption
Use of a 13 Amp time delay circuit breaker is recommended
for private devices and a 16 A breaker for public devices.
In case of sharing the power supply with other devices
please consult a technician in order to dimension a correct
installation.
Variable Rate Pump
To Earth
6
1 2 3
1
1
2
2
3
4
5
6
7
8
1 2 3 4
3
3
4
4
1
1
2
2
4. ELECTRICAL CONNECTIONS
Connection ext. display*
Connection WIFI module
Device control SLAVE
Variable speed pump
*IF connecting 2 displays on
the device, remember not to
connect the second display in
this communication channel.
Use the “ext. Display” socket
instead.
Chlorine probe detector
FL2 (rotameter)
Cover
1
&
5
Conductivity probe
Paddle Flow switch
2
&
5
FL1
Suction lance pH-
Minus
TANK
4
&
5
Temperature probe
pHredoX
Free chlorine
pH
pH dosing pump
1
&
2
AUX 4
Heating control
13
&
14
AUX 3
ACO
®
11
&
12
LIGHT
Lighting control
9
&
10
AUX 2
Besgo backwash
valve
5
&
6
FILTER PUMP
Filtration control
14
12
11
A1 A2
LN
AUX 1
Dosing pump occulation
APF
®
3
&
4
3
black
5
brown
6
blue
1
red
2
yellow
3
black
1
yellow
2
transparent
1
slow
2
medium
3
fast
4
common
1
red
2
yellow
3
green
4
black
3
red
4
black
1
brown
2
blue
7
&
8
CONNECT ALL THE SENSORS CAREFULLY, A
BAD CONNECTION MAY CAUSE IRREPARABLE
DAMAGE TO THE DEVICE
1
2
3
1
2
3
1 2 3 4 5
6
7 8 9
10
11
12
13 14
DRY CONTACT110-230 V max. 3.15 A
2
EN