[005] System Times
'HIDXOW 9DOLGHQWULHV>@
030
I_______I_______I_______I Entry Delay 1 (in seconds) and 5.18 Entry/Exit Delay Options on page 23)
045
I_______I_______I_______I Entry Delay 2 (in seconds) and 5.18 Entry/Exit Delay Options on page 23)
120
I_______I_______I_______I Exit Delay (in seconds) and 5.18 Entry/Exit Delay Options on page 23)
004 I_______I_______I_______I Bell Cut-off (in minutes) and 5.13 Bell on page 21)
[006] Installer’s Code
(Section 4.1 Installers Programming on page 11)
'HIDXOW
1565
I_______I_______I_______I_______I
[007] Master Code
(Section 5.1 Programming Security Codes on page 13)
'HIDXOW
1234
I_______I_______I_______I_______I
[008] Maintenance Code
(Section 5.1 Programming Security Codes on page 13)
'HIDXOW
AAAA
I_______I_______I_______I_______I
[009] PGM Output Programming (PGM 1 and 2)
(Section 5.11 PGM Output Options on page 19)
3URJUDPPDEOH2XWSXW2SWLRQV
 Burglary and Fire Bell Output  Ground Start Pulse
 For future use  Remote Operation (DLS-1 Support)
 Sensor Reset  For future use
 For future use  Away Armed Status
 System Armed Status  Stay Armed Status
 Ready To Arm  Command Output #1 ([*][7][1])
 Keypad Buzzer Follow Mode  Command Output #2 ([*][7][2])
 Courtesy Pulse  For future use
 System Trouble Output (with Trouble options)  For future use
 System Event [Strobe (with Event options)]  Silent 24 Hour (PGM2 Only)
 System Tamper (all sources: zones, kpd, modules)  Audible 24 Hour (PGM2 Only)
 TLM and Alarm  For future use
 Kissoff Output  Battery Test
127(2XWSXWW\SHV>@DQG>@FDQQRWEHXVHGWRJHWKHURQWKHVDPHV\VWHP
'HIDXOW 'HIDXOW
10
I_______I_______I PGM 1 19 I_______I_______I PGM 2
3URJUDP3*02SWLRQ$WWULEXWHVLQVHFWLRQV>@>@
[012] Keypad Lockout Options
(Section 5.21 Keypad Lockout Options on page 23)
127(,I.H\SDG/RFNRXWLVDFWLYHWKHSDQHOFDQQRWEHGLVDUPHGZLWKDNH\VZLWFK
'HIDXOW
000
I_______I_______I_______I Number of Invalid Codes Before Lockout (001-255 codes)
000
I_______I_______I_______I Lockout Duration (001-255 minutes)
[013] First System Option Code
'HIDXOW 2SWLRQ 21 2II 6HFWLRQ3DJH
OFF
I________I 1 Normally Closed Loops End-of-Line Resistors 2.8 5
OFF
I________I 2 Double End-of-Line Resistors Single End-of-Line Resistors 2.8 5
ON*
I________I 3 Panel shows all troubles when armed Panel shows only Fire troubles when armed 3.4 7
OFF I________I 4 Tampers/Faults do not show as open Tampers/Faults show as open 3.4 7
OFF
I________I 5 For future use
ON
I________I 6 Audible Exit Fault Enabled Audible Exit Fault Disabled 5.18 23
ON I________I 7 Event Buffer Follows Swinger Shutdown Event Buffer Logs Events Past shutdown 5.20 23
OFF
I________I 8 For future use
* Option 3 must be OFF if LCD keypads older than v2.0 are used.