[005] System Times
'HIDXOW 9DOLGHQWULHV>@
030
I_______I_______I_______I Entry Delay 1 (in seconds) and 5.18 “Entry/Exit Delay Options” on page 23)
045
I_______I_______I_______I Entry Delay 2 (in seconds) and 5.18 “Entry/Exit Delay Options” on page 23)
120
I_______I_______I_______I Exit Delay (in seconds) and 5.18 “Entry/Exit Delay Options” on page 23)
004 I_______I_______I_______I Bell Cut-off (in minutes) and 5.13 “Bell” on page 21)
[006] Installer’s Code
(Section 4.1 “Installer’s Programming” on page 11)
'HIDXOW
1565
I_______I_______I_______I_______I
[007] Master Code
(Section 5.1 “Programming Security Codes” on page 13)
'HIDXOW
1234
I_______I_______I_______I_______I
[008] Maintenance Code
(Section 5.1 “Programming Security Codes” on page 13)
'HIDXOW
AAAA
I_______I_______I_______I_______I
[009] PGM Output Programming (PGM 1 and 2)
(Section 5.11 “PGM Output Options” on page 19)
3URJUDPPDEOH2XWSXW2SWLRQV
Burglary and Fire Bell Output Ground Start Pulse
For future use Remote Operation (DLS-1 Support)
Sensor Reset For future use
For future use Away Armed Status
System Armed Status Stay Armed Status
Ready To Arm Command Output #1 ([*][7][1])
Keypad Buzzer Follow Mode Command Output #2 ([*][7][2])
Courtesy Pulse For future use
System Trouble Output (with Trouble options) For future use
System Event [Strobe (with Event options)] Silent 24 Hour (PGM2 Only)
System Tamper (all sources: zones, kpd, modules) Audible 24 Hour (PGM2 Only)
TLM and Alarm For future use
Kissoff Output Battery Test
127(2XWSXWW\SHV>@DQG>@FDQQRWEHXVHGWRJHWKHURQWKHVDPHV\VWHP
'HIDXOW 'HIDXOW
10
I_______I_______I PGM 1 19 I_______I_______I PGM 2
3URJUDP3*02SWLRQ$WWULEXWHVLQVHFWLRQV>@>@
[012] Keypad Lockout Options
(Section 5.21 “Keypad Lockout Options” on page 23)
127(,I.H\SDG/RFNRXWLVDFWLYHWKHSDQHOFDQQRWEHGLVDUPHGZLWKDNH\VZLWFK
'HIDXOW
000
I_______I_______I_______I Number of Invalid Codes Before Lockout (001-255 codes)
000
I_______I_______I_______I Lockout Duration (001-255 minutes)
[013] First System Option Code
'HIDXOW 2SWLRQ 21 2II 6HFWLRQ3DJH
OFF
I________I 1 Normally Closed Loops End-of-Line Resistors 2.8 5
OFF
I________I 2 Double End-of-Line Resistors Single End-of-Line Resistors 2.8 5
ON*
I________I 3 Panel shows all troubles when armed Panel shows only Fire troubles when armed 3.4 7
OFF I________I 4 Tampers/Faults do not show as open Tampers/Faults show as open 3.4 7
OFF
I________I 5 For future use
ON
I________I 6 Audible Exit Fault Enabled Audible Exit Fault Disabled 5.18 23
ON I________I 7 Event Buffer Follows Swinger Shutdown Event Buffer Logs Events Past shutdown 5.20 23
OFF
I________I 8 For future use
* Option 3 must be OFF if LCD keypads older than v2.0 are used.