1.1 Specifications
Downloading Software Support
• PC1565 v2.1DJRU uses DLS-1 v6.6P and higher.
Flexible Zone Configuration
• Six fully programmable zones; system expandable to
eight zones using keypad zone inputs and wireless
zones
• 38 access codes: one master code, one maintenance
code, two duress codes, two supervision codes and 32
general access codes
• 28 zone types; 8 programmable zone attributes
• Normally closed, single EOL and double EOL zone wiring
• Eight wireless zones available using the PC5132 Wireless
Receiver
Audible Alarm Output
• 700mA Supervised Bell Output (current limited at 3
amps), 12Vdc
• Steady or Pulsed Output
EEPROM Memory
• Does not lose programming or system status on com-
plete AC and Battery failure
Programmable Outputs
• One programmable voltage output and one programma-
ble voltage output/input; 20 programmable options
• PGM1 = 300mA; PGM2 = 50mA
Powerful 1.5 Amp Regulated Power Supply
• 550 mA Auxiliary Supply, 12 V
DC
• Positive Temperature Coefficient (PTC) components
replace fuses
• Supervision for loss of AC power, low battery
Power Requirements
• Transformer = 16 V
AC
, 40VA (Secondary)
• Battery = 12V 4Ah minimum rechargeable sealed lead
acid battery (battery not supplied by DSC).
Remote Keypad Specifications
• Three keypads available:
- PC1555RKZ eight zone LED keypad with zone input
- PC5508Z eight zone LED keypad with zone input
- LCD5500Z alphanumeric keypad with zone input
- LCD5501Z fixed message LCD keypad with zone input
- LCD5501ZT32-433 keypad / receiver
• All keypads have five programmable function keys
• Connect up to eight keypads
• 4-wire (Quad) connection to Keybus
• Built in piezoelectric buzzer
Digital Communicator Specifications
• Supports major communication formats including SIA
and Contact ID
• Event-initiated personal paging
• Three programmable telephone numbers
• Two account numbers
• Supports LINKS2X50 Long Range Radio Transmitter
• DTMF and pulse dialing
• DPDT line seizure
• Anti-jam feature
• Split reporting of selected transmissions to each tele-
phone number
System Supervision Features
The PC1565 continuously monitors a number of possible trou-
ble conditions including:
• AC power failure • AUX Power Supply Trouble
• Fault by zone • Loss of internal clock
• Tamper by zone • Bell output trouble
• Fire trouble • Telephone line trouble
• Failure to communicate • Low battery condition (panel)
• Low battery by device (wireless)
• Module fault (supervisory or tamper)
False Alarm Prevention Features
• Audible Exit Delay • Quick Exit
• Audible Exit Fault • Cross Zone Burglary Alarm
• Communication Delay • Rotating Keypress Buffer
• Urgency on Entry Delay
Additional Features
• Auto Arm at specified time
• Keypad-activated alarm output and communicator test
• All modules connect to the system via a four wire Keybus
up to 1000’/305m from main panel
• An event buffer which records the past 128 events with
both the time and date at which they occurred; buffer can
be printed using PC5400 serial interface module, or
viewed with the LCD5500Z keypad.
• Supports the addition of the PC5132 wireless receiver for
integration of wireless devices
• Uploading and downloading capability
• Local downloading capability through the use of the
PC-LINK adaptor
• Added Keybus fault protection: clock and data outputs
have been programmed to withstand shorts to +12v to
prevent control panel damage