Programming Worksheets
[014] Second System Option Code
'HIDXOW 2SWLRQ 21 2II 6HFWLRQ 3DJH
OFF
I________I 1 Arm / Disarm Bell Squawk enabled Arm / Disarm Bell Squawk disabled 5.17 22
OFF
I________I 2 Bell Squawk During Auto Arm No Bell Squawk During Auto Arm 5.18 23
OFF
I________I 3 Bell Squawk On Exit Delay No Bell Squawk On Exit Delay 5.18 23
OFF
I________I 4 Bell Squawk On Entry Delay No Bell Squawk On Entry Delay 5.18 23
OFF
I________I 5 Bell Squawk On Trouble No Bell Squawk On Trouble 3.4 7
ON
I________I 6 Audible Exit with Urgency Silent Exit Delay 5.18 23
OFF
I________I 7 Exit Delay Termination Enabled Exit Delay Termination Disabled 5.18 23
OFF
I________I 8 Fire Bell is Continuous Fire Bell Follows Bell Cut-off 5.13 21
[015] Third System Option Code
'HIDXOW 2SWLRQ 21 2II 6HFWLRQ3DJH
ON I________I 1 Fire Keys Enabled Fire Keys Disabled 5.16 22
OFF
I________I 2 Panic Keys Audible (Bell / Beeps) Panic Keys Silent 5.16 22
OFF
I________I 3 Quick Exit Enabled Quick Exit Disabled 3.4 7
ON*
I________I 4 Quick Arming Enabled Quick Arming Dis. / Function keys Req. Code 3.4 7
OFF
I________I 5 Code Required For Bypassing No Code Required 3.4 7
OFF
I________I 6 Master Code Not Changeable Master Code Changeable 5.1 13
ON
I________I 7 TLM Enabled TLM Disabled 5.12 21
OFF
I________I 8 TLM Audible (Bell) When Armed TLM Trouble Beeps When Armed 5.12 21
* When using a PC5132 version 2.1 or older with a Wireless Key, option [4] must be ON for the Arm button to work.
[016] Fourth System Option Code
'HIDXOW 2SWLRQ 21 2II 6HFWLRQ3DJH
ON
I________I 1 AC Trouble Displayed AC Trouble Not Displayed 3.4 7
OFF
I________I 2 Trouble Light Flashes if AC Fails Trouble Light Does Not Follow AC Status 3.4 7
OFF
I________I 3 Blank Keypad When Not Used Keypad Active Always 5.22 23
OFF
I________I
4 Code Required to Remove Kypd Blanking No Code Required 5.22 23
ON I________I 5 Keypad Backlighting is enabled Keypad Backlighting is disabled 5.23 24
OFF
I________I 6 Power Save Mode enabled Power Save Mode disabled 5.22 23
OFF
I________I 7 Bypass Status Displayed While Armed Bypass Status Not Displayed While Armed 5.17 22
OFF
I________I 8 Keypad Tampers enabled Keypad Tampers disabled 5.25 24
[017] Fifth System Option Code
'HIDXOW 2SWLRQ 21 2II 6HFWLRQ 3DJH
ON I________I 1 Unident. Wireless Key Disarm Enabled Disabled 5.17 22
OFF
I________I 2-8 For future use
[018] Sixth System Option Code
'HIDXOW 2SWLRQ 21 2II 6HFWLRQ 3DJH
OFF
I________I 1 Troubles are Latching Troubles Follow Restore 3.4 7
OFF
I________I 2 Engineer's Reset Enabled Engineer's Reset Disabled 5.27 24
OFF
I________I 3 Automatic Battery Check Enabled Normal Battery Tests Only 2.2 3
OFF
I________I 4 Contact I.D. Partial Close Identifier is 5 Partial Close Identifier is 4 5.9 17
OFF
I________I 5-8 For future use