PC2550 Version 1.2
[17] 3rd System Option Code
Page 20
Default Zone Light On Zone Light Off
Off
Zone Light 1 ...................... No bell during auto-arm Bell during auto-arm
Off
Zone Light 2 ...................... AC excluded from trouble AC included
Off Zone Light 3 ...................... 60 second shunt on power up Zones active on power up
Off
Zone Light 4 ...................... Auto-arm cancel req. access code No code required
Off
Zone Light 5 ...................... Home-Away with delay Home-Away as interior
Off
Zone Light 6 ...................... Force arm on auxiliary delay Auxiliary delay normal
Off Zone Light 7 ...................... TX limit to 24 hr. period TX limit to armed period
Off
Zone Light 8 ...................... Show bypass status always Show bypass status/disarmed
[18] 4th System Option Code
Page 20
Note: Quick exit shall not be enabled on UL listed systems.
Default Zone Light On Zone Light Off
Off
Zone Light 1 ...................... Quick exit enabled Quick exit disabled
Off Zone Light 2 ...................... Bell pulses always Bell pulses upon fire only
Off
Zone Light 3 ...................... Show bypassed zones/armed Bypass display normal
Off
Zone Light 4 ...................... 2 min keypad timeout enabled 2 min keypad timeout disabled
Off
Zone Light 5 ...................... Partial close on auto-arm No partial close on auto-arm
Off Zone Light 6 ...................... Keypad [P]anic silent buzzer Keypad [P]anic audible buzzer
Off
Zone Light 7 ...................... [F]ire key disabled [F]ire key enabled
Off
Zone Light 8 ...................... Bell shutdown active Bell shutdown not active
[19] Zones 1 to 8 Bypass Mask
Page 20
Default
On
Zone Light 1
On
Zone Light 2
On Zone Light 3
On
Zone Light 4
On
Zone Light 5
On
Zone Light 6
On Zone Light 7
On
Zone Light 8
[20] System Times
Page 21
Default
30
Entry Delay Time (in sec.)
45 Exit Delay Time (in sec.)
04
Bell Cut-off Time (in min.)
30 AC Failure Transmission Delay (in min.)
50 Normal Zone Response Time (x 10 ms)
30
Test Transmission/Periodic Download Cycle Time (in days)
Note:
If zone light is on, the zone can be
bypassed using the [
] [1] command.
Notes:
1.Valid entries are: 01 to 99.
2.Do not enter “00” - it is not a valid
entry.
For UL commercial installations the bell
cut-off time shall be a minimum of 15
minutes.