30
PC2550 Version 1.3
[18] 4th System Option Code
Page 19
Default Zone Light On Zone Light Off
Off
Zone Light 1 ...................... Quick exit enabled Quick exit disabled
Off Zone Light 2 ...................... Bell pulses always Bell pulses upon fire only
Off
Zone Light 3 ...................... Show bypassed zones/armed Bypass display normal
Off
Zone Light 4 ...................... 2 min keypad timeout enabled 2 min keypad timeout disabled
Off
Zone Light 5 ...................... Partial close on auto-arm No partial close on auto-arm
Off Zone Light 6 ...................... Keypad [P]anic silent buzzer Keypad [P]anic audible buzzer
Off
Zone Light 7 ...................... [F]ire key disabled [F]ire key enabled
Off
Zone Light 8 ...................... Bell shutdown active Bell shutdown not active
[19] Zones 1 to 8 Bypass Mask
Page 20
Default
On Zone Light 1
On Zone Light 2
On
Zone Light 3
On
Zone Light 4
On
Zone Light 5
On Zone Light 6
On
Zone Light 7
On
Zone Light 8
[20] System Times
Page 20
Default
030 Entry Delay Time (in seconds)
120 Exit Delay Time (in seconds)
004
Bell Cut-off Time (in minutes)
030 AC Failure Transmission Delay (in minutes)
050
Normal Zone Response Time (x 10 ms)
030 Test Transmission/Periodic Download Cycle Time (in days)
[21] Auxiliary Delay Zone Times
Page 20
Default
045 Entry Time (in seconds)
180
Exit Time (in seconds)
[22] Communication Variables
Page 20
Default
03 Maximum transmissions until swinger shutdown
Enter digits from 01 to 99 for number of transmissions per zone during the period as
defined in section [17], 3rd system option code, zone light 7.
00 = Unlimited transmissions per burglary zone (Fire zone never shuts down).
00
Delay Before Transmission (Burglary Zones only)
Enter digits from 00 to 99 - delay in seconds.
00 = No delay (Fire zone and 24 hr. zones always transmit without delay).
Transmission delay as programmed here is for burglary zones only.
Note:
If zone light is on, the zone can be
bypassed using the [
] [1] command.
Notes:
1.Valid entries are: 001 to 255.
2.Do not enter 000 - it is not a valid entry.
Note:
Valid entries are: 001 to 255.

Table of Contents