PC2550 Version 1.3
[30] Programmable Input and Output Options
Page 22
Default
2
Auxiliary Input Zone Enter 1, 2, 3 or 4 for options below 1, 2, 3 or 4 are the
(Normally open, momentary [1] Silent 24 hour input only valid entries
closure to “Aux +”) [2] Audible 24 hour input
[3] Momentary key arming
[4] Forced answer
2 Programmable Output Enter 0 to F for options below 0 through F are
(A 50 mA switch to ground.) [0] LINKS support output the only valid entries
Note: A relay must be used to
[1] Ground start pulse
obtain more current.
[2] Utility output no access code
[3] Utility output any access code
[4] Utility output Group A access code
[5] Utility output Group B access code
[6] Keypad buzzer follow mode
[7] System status (arm/disarm) output
[8] Strobe output (latched alarm output)
[9] Failure to communicate output
[A] TLM and alarm
[B] Courtesy pulse
[C] PGM squawk output
[D] 2nd line slave
[E] Kissoff output
[F] Remote operation
(DLS-1 version 5.3 or later)
Note: Section [31]...[34] are used for split arming or split reporting only.
[31] Zone Group A Assignment
Page 23
Default
On Zone Light 1
On Zone Light 2
On
Zone Light 3
On Zone Light 4
On
Zone Light 5
On Zone Light 6
On Zone Light 7
On
Zone Light 8
[32] Zone Group B Assignment
Page 23
Default
On
Zone Light 1
On Zone Light 2
On
Zone Light 3
On Zone Light 4
On Zone Light 5
On
Zone Light 6
On Zone Light 7
On
Zone Light 8
Note: If zone light is on that zone is assigned to
Group A.
If light is on in sections [31] and [32], the zone is
common to both sides and will only be armed if both
sides are armed.
Note:
If zone light is on that zone is assigned to
Group B.
If light is on in sections [31] and [32], the zone is
common to both sides and will only be armed if both
sides are armed.