29000592 R2
PC2550
Notice of Software Release
PC2550 software version 1.3 has now been released.
Several new features have been added to reduce the possibility of user caused false
alarms. And also, additional features have been added to provide further support for the
LINKS 1000 and Escort.
These changes are outlined in the following programming sections.
[17] 3rd System Option Code Page 18
120 second bypass of zones on power up.
[20] System Times Page 20
System Times now allow more than 4 minutes of Entry or Exit Delay. It provides
users additional time when circumstances warrant. The default setting of Exit
Delay is 120 seconds.
[30] Programmable Input and Output Options Page 22
2nd Digit Programmable Output
[C] PGM Squawk Output (for use with options in section [59]).
[48] 5th System Option Code Page 25
Fire Zone on Switched Auxiliary Supply
- Prevents Fire Alarm Circuit Troubles if [][4] is used to reset sensors.
Escort Accepts Master Code Only
- Remote access through the Escort requires the Master Code.
[56] LINKS 1000 Preamble for 1st Telephone Number Page 26
[57] LINKS 1000 Preamble for 2nd Telephone Number Page 26
[58] LINKS 1000 Preamble for Downloading Telephone Number Page 26
The LINKS 1000 preambles are 4 digit numbers which are used for programming area
codes in cases where the LINKS must call long distance.
[59] 6th System Option Code Page 26
PGM Squawk on Exit Delay - The PGM Output will squawk for the Exit Delay.
PGM Squawk on Entry Delay - The PGM Output will squawk for the Entry Delay.
Audible Exit Fault - The user is warned that a delay zone was left open when the
exit delay expired.
Audible Exit Delay with Urgency - The keypad sounds a pulsing tone for the exit
delay and sounds a faster pulsing tone for the last 10 seconds.
Urgency Applied to Entry Delay - The keypad pulses the steady entry delay
tone for the last 10 seconds.
Closing Confirmation - The keypad will sound a series of beeps when the
closing code has been successfully transmitted.
Exit Delay Termination - The exit delay is cancelled when a standard delay zone
is restored.
Note: Downloading Software DLS-1 Version 5.3 must be used to upload/download the new PC2550