7
KEYPAD FUNCTIONS
Introduction
The Keypad provides complete control of the PC560 control panel. The system can be completely programmed
from the keypad. The 4 zone lights provide alarm and status indication for the alarm circuits, and three function
lights advise the user of system status. The built-in sounder lets the user hear correct key entries and other alert
signals. Keypad alarms may be activated by pressing and holding the [F], [A] or [P] Keys. Note that all keypad
entries are made by pressing one key at a time.
Master Code
A default Master Code “1234” is factory programmed into the PC560. The Master Code is used to arm and
disarm the system, to silence the bell or siren after an alarm, and to program additional Access Codes. The
Master Code may be changed by the user through the [
][5][Master Code] Program Access Codes command.
Installer’s Programming Code
A default Installer’s Programming Code “0560” is programmed into the PC560. Using this code and the [
][8]
command, the installer can perform programming functions. This code should be changed by the installer after
the system is installed.
Arming
Before arming the system, close all protected doors and windows and stop movement in areas protected by
motion detectors. If the “System” light is on, check for possible trouble conditions (refer to [
][2]: Display
Troubles) and correct the condition. Ensure that any bypassed zones are bypassed intentionally; refer to
[
][1][Access Code]: Bypass Zones. If the “Ready” light is not on, one or more zones are open; the system
can only be armed when the “Ready” light is ON.
To arm the system, enter a 4-digit Access Code. As each digit is entered, the keypad sounder will beep. When
the Access Code has been entered, the “Armed” light will come ON and the keypad will beep 6 times. If the
Access Code has been entered incorrectly, the keypad will sound a single long tone; press the [#] Key and enter
the Access Code again.
When an Access Code has been entered and the “Armed” light is ON, leave the premises through the
designated Entry-Exit door before the Exit Delay expires. At the end of the Exit Delay, all lights on the keypad
will be shut OFF except for the “Armed” light.
The default setting for the Exit Delay is 60 seconds. Refer to Programming Section [01] Zone Definitions for
information on zone types that are affected by the Exit Delay. Also refer to Programming Section [02] for
instructions on changing the Exit Delay. If an alarm occurs during the armed period, the Zone Light for the
affected zone will remain ON until the system is disarmed.
Auto-Bypass/Home-Away Arming
If an Access Code is entered and the Exit-Entry zone is not activated during the Exit Delay, the system will arm
with all Home-Away zones automatically bypassed. If the Exit-Entry zone is activated during the Exit Delay, the
Home-Away zones will not be bypassed. If a standard Delay zone is activated while the system is armed, all
automatic bypasses will be removed.
This feature is designed for the user who wishes to remain at home with the system armed. When this feature
is enabled, the user does not have to manually bypass the interior zones.
At-Home Arming
When [
][9] is entered to arm the system, the system will arm as described above in Auto-Bypass/Home-Away
Arming. However, an exit may be made through the Entry-Exit Zone during the Exit Delay; at the end of the Exit
Delay, the system will be armed and Home-Away zones will be automatically bypassed. Note that the Entry
Delay will still be applied to standard Delay zones.
FOR THE RECORD
Customer ___________________________________________________________________________________
Address ___________________________________________________________________________________
___________________________________________________________________________________
Phone ________________________________ Installation Date ____________________________
CONTACTS
Name ________________________________ Phone ________________________
Name ________________________________ Phone ________________________
Name ________________________________ Phone ________________________
ZONE INFORMATION
Zone Type Protected Area
1 ____________________ _______________________________________________________
2 ____________________ _______________________________________________________
3 ____________________ _______________________________________________________
4 ____________________ _______________________________________________________
Entry Delay ________________________________
Exit Delay ________________________________
Bell Cutoff ________________________________
KEYPAD ZONES
[P] Key
Silent Audible
NOTES
18
PC560 v1.0A