Chapter 6.0 Trouble Conditions
Trouble
Condition
Trouble
#
Level 1
Description
Trouble
Types
Trouble
#
Level 2
Trouble
Notification
Level 3
Battery Trouble 02 The system has detected a bat-
tery trouble condition. Call
for service.
Low Battery
(System
Label)
01 n/a
No Battery
service (Sys-
tem Label)
02
n/a
High Current
Output Low
Battery
04 Module 1-4
High Current
Output No
Battery
05 Module 1-4
Power Supply
Low Battery
07 Module 1-4
Power Supply
No Battery
08 Power supply
1-4
Bus Voltage 03 A module has detected a low
voltage on its corbus red ter-
minal.
HSM2HOST 01 n/a
Keypad 02 Keypad 1-16
Zone
Expander
04 Zone
expander 1-
15
Power Supply 05 Power supply
1-4
High Current
Output
06 Output ter-
minal 1-4
Output
Expander
08 Output mod-
ule 1-16
HSM2955
Bus Voltage
(Audio
Expander)
09
n/a
AC Troubles 04 The system is experiencing
loss of power. Call for ser-
vice.
If the building and/or neigh-
borhood has lost electrical
power, the system will con-
tinue to operate on battery for
several hours.
Zone 01 Zone label or
001-128
Siren 03 Siren 1-16
Repeater 04 Repeater 1-8
Power Supply 05 Power supply
1-4
High Current
Output
06 Output ter-
minal 1-4
System Label 07 n/a
- 17 -

Other manuals for DSC PowerSeries Neo HS2016-4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC PowerSeries Neo HS2016-4 and is the answer not in the manual?

DSC PowerSeries Neo HS2016-4 Specifications

General IconGeneral
BrandDSC
ModelPowerSeries Neo HS2016-4
CategorySecurity System
LanguageEnglish

Related product manuals