asshown in the diagramincluded in thismanual.
2. The HSPA3G Cellularpath is immune to conducted and radiated RF fields
with levelsup to 10V/mastested per EN50130- 4 Standard.
3. The TL2803G(R)E-EU/3G2080(R)E-EU/TL280(R)Emodule conforms with
radiated emissionslevelsforClassBequipment asperstandardsEN61000-
6-3/EN55022/CISPR22.
4. The TL2803G(R)E-EU/3G2080(R)E-EU/TL280(R)Emodule usesAES128
encryption and heartbeat supervision for HSPA3GCellularcommunication
pathsand it meetssecuritylevelsS2 asper EN50136-2:2013. It also uses
authentication for each message exchanged with the compatible receiver
equipment at ARC and itmeetslevelI2 forinformation security.
5. The 3G2080(R)E-EU module hasonlyone communication path:
HSPA3GCellularcommunication path using 900/1800/2100MHzPublicCel-
lularNetwork. The HSPA3GCellular communication path that can be used in
a standalone mode in conjunction with a DSC alarmsystem(compatible DSC
alarmcontrolpanelmodels: HS2128/064/032/016). The supported ATScon-
figuration is: customcategoryC.
6. The TL280(R)Emodule hasonlyone communication path: Ethernet com-
munication path using Internet. The communication path that can be used in
a standalone mode in conjunction with a DSC alarmsystem(compatible DSC
alarmcontrolpanelmodels: HS2128/064/032/016). The supported ATScon-
figuration is: customcategoryC.
7. The TL2803G(R)E-EU module hastwo communication paths:HSPA3GCel-
lularcommunication path using 900/1800/2100MHzPublicCellularNetwork
and Ethernet communication path using Internet. The communication paths
can be used in a standalone mode in conjunction with a DSC alarmsystem
(compatible DSC alarmcontrolpanelmodels: HS2128/064/032/016).The
supported ATSconfiguration is: customcategoryC.
8. TL2803G(R)E-EU/3G2080(R)E-EU/TL280(R)Ehas been tested forcom-
pliance in conjunction with the following applicable standards: EN50136-
1:2012, EN50136-2:2013, EN50131-10:2014, ATSconfiguration: C.
For EN50131- 1:2006/A1:2009 compliant installations, the following pro-
gramming optionsshallbe set asdescribed.
Supervision Heartbeat:
•shallbe set to 180 seconds
NOTE:The compatible receiver at ARC location shall have supervision window
programmed for 180 seconds. TL2803G(R)E-EU/3G2080(R) E-EU/TL280(R)E
has been certified by TELEFICATION in accordance with EN50131-
1:2006/A1:2009, EN50131- 10:2014 requirements for Grade 2, Class II and
EN50136-2:2013 Configuration: C
ATS Custom Category C Level
EN50136-1:2012 AnnexD Table D.1 D3
EN50136-1:2012 AnnexD Table D.2 M3
EN50136-1:2012 AnnexD Table D.3 T4
EN50136-1:2012 AnnexD Table D.4 A4 (Depending on cellularcarrier used)
EN50136-1:2012 AnnexD Table D.5
S2 (use AES- 128 and
authentication/sequential information
in each message transmitted to the SG
receiver)
EN50136-1:2012 AnnexD Table D.6 I2 (use AES-128 encryption)
EN50136-1:2012 Table 1
Use single communication path for
models 3G2080 (R) E- EU (cellular
network), TL280 (R)E (Ethernet port)
and two communication paths for
model TL2803G (R) E- EU
(cell/Ethernet).
EN50136-1:2012 Table 4 ATSfailure reported to ARC
EN50136-1:2012 Table 5
ATS failure reported to AS (DSC
compatible control panel
HS2128/HS2064/HS2032/HS2016)
EN50136-1:2012 Table 6
There is no recording of availability
failure
EN50136-2:2013 Table 1 No logging function provided
EN50136-2:2013 Table 2
No memory provided for logging
function
EN50136-2:2013 Table 3 ATSfailure reported to ARC
+HUHE\'6&GHFODUHVWKDWWKLVGHYLFHLVLQFRPSOLDQFHZLWKWKHHVVHQWLDO
UHTXLUHPHQWVDQGRWKHUUHOHYDQWSURYLVLRQVRI'LUHFWLYH(&
7KHFRPSOHWH577('HFODUDWLRQRI&RQIRUPLW\FDQEHIRXQGDW
KWWSZZZGVFFRPOLVWLQJVBLQGH[DVS[
&=('6&MDNRY¿UREFHSURKODģXMHŀHWHQWRY¿UREHNMHYVRXODGXVHYģHPL
UHOHYDQWQ¯PLSRŀDGDYN\VPÝUQLFH(&
'$1'6&HUNO¨UHUKHUYHGDWGHQQHNRPSRQHQWHQRYHUKROGHUDOOHYLNWLJHNUDYVDPW
DQGUHEHVWHPPHOVHUJLWWLGLUHNWLY(&
'87+LHUELMYHUNODDUW'6&GDWGLWWRHVWHOLQRYHUHHQVWHPPLQJLVPHWGHHLVHQHQ
EHSDOLQJHQYDQULFKWOLMQ(&
),1'6&YDNXXWWDDODLWWHHQW¦\WW¦Y¦QGLUHNWLLYLQ(&ROHQQDLVHWYDDWLPXNVHW
)5(3DUODSU«VHQWH'6&G«FODUHTXHFHGLVSRVLWLIHVWFRQIRUPHDX[H[LJHQFHV
HVVHQWLHOOHVHWDXWUHVVWLSXODWLRQVSHUWLQHQWHVGHOD'LUHFWLYH(&
*(5+LHUGXUFKHUNO¦UW'6&GD¡GLHVHV*HU¦WGHQHUIRUGHUOLFKHQ%HGLQJXQJHQXQG
9RUUDXVHW]XQJHQGHU5LFKWOLQLH(&HQWVSULFKW
*5(˂˜˞˱ˬ˲˭˞ˮ˹˪˱ˬ˯ˤ'6&ˡˤ˨˻˪ˢ˦˹˱˦˞˲˱˛ˤ˰˲˰˧ˢ˲˛ˢ˜˪˞˦˰˺˩˳˶˪ˤ˩ˢ˱˦˯
ˬ˲˰˦˻ˡˤ˯˞˭˞˦˱˛˰ˢ˦˯˧˞˦˩ˢ˹˨ˢ˯˱˦˯˙˨˨ˢ˯˰˴ˢ˱˦˧˚˯˞˪˞˳ˬˮ˚˯˱ˤ˯ˍˡˤˠ˜˞˯(&
,7$&RQODSUHVHQWHOD'LJLWDO6HFXULW\&RQWUROVGLFKLDUDFKHTXHVWRSURGRWWRª
FRQIRUPHDLUHTXLVLWLHVVHQ]LDOLHGDOWUHGLVSRVL]LRQLULOHYDQWLUHODWLYHDOOD'LUHWWLYD
&(
125'6&HUNO¨UHUDWGHQQHHQKHWHQHULVDPVYDUPHGGHJUXQQOHJJHQGHNUDYRJ
ºYULJHUHOHYDQWHNUDYLGLUHNWLY()
32/'6&RĝZLDGF]DľHXU]ÇG]HQLHMHVWZ]JRGQRĝFL]]DVDGQLF]\PLZ\PDJDQLDPL
RUD]SR]RVWDĄ\PLVWRVRZQ\PLSRVWDQRZLHQLDPL'\UHNW\Z\:(
3253RUHVWHPHLRD'6&GHFODUDTXHHVWHHTXLSDPHQWRHVW£HPFRQIRUPLGDGH
FRPRVUHTXLVLWRVHVVHQFLDLVHRXWUDVGHWHUPLQD©·HVUHOHYDQWHVGD'LUHFWLYD
(&
63$3RUODSUHVHQWH'6&GHFODUDTXHHVWHHTXLSRHVW£HQFRQIRUPLGDGFRQORV
UHTXLVLWRVHVHQFLDOHV\RWURVUHTXLVLWRVUHOHYDQWHVGHOD'LUHFWLYD(&
6:('6&EHNU¦IWDUK¦UPHGDWWGHQQDDSSDUDWXSSI\OOHUGHY¦VHQWOLJDNUDYHQRFK
DQGUDUHOHYDQWDEHVW¦PPHOVHUL'LUHNWLYHW(&
UL/ULC Installation Requirements
NOTE:For equipment used at the protected premisesand intended to facilitate
IP communications (hubs, routers, NIDs, Digital Subscriber Line (DSL), cable
modems), 24 hourbackup powerisrequired. Where such cannot be facilitated, a
secondary(back-up)communication channelisrequired.
Domain Name Service (DNS) programming is not permitted in
UL1610 listed systems.
Technical Specifications
The input voltage to the Communicatorcan be drawn fromthe UnderwritersLab-
oratories/UnderwritersLaboratoriesCanada (UL/ULC)listed controlpanel.
Notes for using Private, Corporate, and High Speed Data Net-
works:
Networkaccess and domain access policiesshall be set to restrict unauthorized
networkaccess, and spoofing orDenialof Service (DoS)attacks. Select an Inter-
net Service Provider (ISP)that has redundant servers/systems, back-up power,
routerswith firewallsenabled, and methods to identify and protect against DoS
attacks(e.g., via spoofing).
Notes for using Public Switched and Cellular Data Networks:
Communication channels shall be facilitated such that the communicator will
restrict unauthorized access, which could otherwise compromise security. The
communicatorshallbe located in a secured area.
•For ULC Residential Fire and Burglary applications the TL2803G (R)
E/3G2080(R)E/TL280 (R)E can be used as primary communication channel via
eithercellularorEthernet orasa back-up in conjunction with the DigitalAlarmCom-
municatorTransmitter(DACT).Testtransmission every24 hoursshallbe enabled
on each channel.
•For ULC Commercial Fire and Burglary applications the TL2803G (R)
E/3G2080(R)E/TL280(R)Ecan be used asa passive communication module with
the following securitylevels:
l P1 (each channelcellularorEthernet isindependent)
l P2 (cellularand Ethernet in back-up configuration, panelsection [851][005]
toggle option [5] OFF).
l P3 (cellularand Ethernet in redundant configuration, panelsection [851]
[005] toggle option [5] ON).
The communicator can also be used asan active communication systemwith the
securitylevelsA1-A4 (each channelcellularor Ethernet independent or together
in a back-up/redundant configuration).Foractive line securitysystemsAES128 bit
encryption shall be enabled (at the monitoring station receiver) and the super-
vision heartbeat rate shall be set as 90 seconds (panel section [851] [004] =
005A/90). The supervision window at the Signal Receiver Center (SRC) 's
receivershallbe programmed as maximumof 180 (00B4/180)seconds.
• For UL Residential Fire and Burglary applications the TL2803G (R)
E/3G2080R/TL280(R)E can be used as the primary communication channel via
eithercellularor Ethernet, or asa back-up in conjunction with the DACT (30 day
testtransmission isrequired on each channel).
• For UL Commercial Burglary applications the TL2803G (R)
E/3G2080R/TL280(R)E can be used as dualsignalling line communication sys-
tem(cellularand Ethernet channels used in redundant configuration), standard
line securityand asencrypted line security.
•The supervision heartbeat shall be enabled (panelsection [851] [005] toggle
option [1] (Ethernet) and/or toggle option [2] (cellular)shallbe ON), toggle option
[3] (supervision type) shall be ON and the supervision heartbeat rate shall be
selected as135 (0087/135)seconds.Option [004] = 0087. The supervision win-
dow at the supervising station shall be maximum200 (00C8/200) seconds. For
18