Section 8: Programming Descriptions
35
Section [013] First System Options
Section [014] Second System Options
Section [015] Third System Options
Option Description
[1] ON: Hardwired Zone 33 enabled. OFF: PGM1 Output enabled. Program Zone Definition or PGM option in Section [009]
[2] ON: Hardwired Zone 34 enabled. OFF: PGM2 Output enabled. Program Zone Definition or PGM option in Section [009]
[3]-[5] Future Use
[6] ON: Audible Exit Fault Enabled. If a delay zone is not secured correctly and not force-armed, at the end of the exit delay, the
system will go into entry delay and turn ON the bell output. OFF: Audible Exit Fault Disabled. The keypad will sound the entry
delay through the keypad.
[7] ON: Event Buffer Follows Swinger Shutdown. The system will NOT log additional alarms for a zone that has reached the swinger
shutdown threshold. OFF: Event Buffer Logs Past Shutdown. All zone alarms will be logged.
[8] ON: Temporal Three Fire Signal Enabled. Temporal Three Fire Signal is used to annunciate fire alarms
(½ second ON, ½ second OFF, ½ second ON, ½ second OFF, ½ second ON, 1 ½ seconds OFF).
OFF: Standard Pulsed Fire Signal. The system will pulse the bell output
(1 second ON, 1 second OFF).
Option Description
[1] ON: Arm/Disarm Bell Squawk Enabled. The system squawks the bell output once when the system is armed, twice when disarmed
and 3 times when disarming with alarms in memory. OFF: Arm/Disarm Bell Squawk Disabled. The bell output does not activate.
[2] Future Use:
[3] ON: RF Jam Logs after 5 Minutes. The system logs an RF Jam trouble condition if the condition is present for 5 minutes. OFF: RF
Jam Logs after 20 Seconds. The system logs the trouble condition after 20 seconds.
[4] ON: Aux Boost Enabled: When the system is in Power Save mode (AC Trouble) Aux+ output voltage is regulated 12VDC.
OFF: Aux Boost Disabled: Aux+ output voltage is not regulated.
[5] Future Use
[6] ON: Audible Exit with Urgency. The system will beep the keypad once every second, and 3 times a second during the last 10
seconds, during exit delay when the system is armed with a user code or armed in the Away mode.
OFF: Silent Exit Delay.
The keypad will not beep.
[7] Future Use:
[8] ON: Fire Bell is Continuous. The bell output will not time out if a fire alarm occurs. The User must turn off the bell by entering a
valid user code.
OFF: Fire Bell follows Bell Cut-off. The bell output will time out normally.
Option Description
[1] ON: [F] Key Enabled. The keypad [F] fire emergency key will be enabled.
OFF: [F] Key Disabled. The keypad [F] fire emergency key will be disabled.
[2] ON: [P] Key Audible (Bell/Beeps). The keypad [P] panic emergency will generate 3 ack beeps and the bell will activate for the
duration of the BTO or until a code is entered. (The keypad will display “system in alarm”.)
OFF: [P] Key Silent. The keypad [P] emergency key generate a silent panic alarm. The bell will not sound and the keypad will not
display “system in alarm”.
[3] ON: Quick Exit Enabled. the Quick Exit feature will be enabled.
OFF: Quick Exit Disabled. the Quick Exit feature will be disabled.
[4] ON: Quick Arming Enabled. The Quick Arming [][0] feature will be enabled.
OFF: Quick Arming Disabled. Quick Arming [][0] feature will be disabled.
If this feature is disabled, a valid user code must be entered after the Stay or Away function buttons are pressed.
[5] ON: Code Required for Bypassing. A valid user code must be entered after pressing [][1] to access the Bypass feature.
OFF: No Code Required. A user code is not required for bypassing.
[6] Future Use
[7] ON: TLM Enabled. The system supervises the telephone line and displays a trouble if disconnected.
OFF: TLM Disabled. The telephone line is not supervised.
WWW.DIYALARMFORUM.COM

Other manuals for DSC PowerSeries

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC PowerSeries and is the answer not in the manual?

DSC PowerSeries Specifications

General IconGeneral
ModelPowerSeries
CategorySecurity System
CommunicationPSTN, IP
Power Supply16.5VAC
Backup Battery12V 7Ah
ProgrammingVia keypad
CompatibilityDSC peripherals and modules

Related product manuals