24
[381] Second Communicator Options
[382] Third Communicator Options
** A Call Waiting Cancel on a non-Call Waiting line will prevent successful connection to the central station.
DLS Downloading
[401] Downloading Options
[402] DLS Downloading Telephone Number (32 Digits)
|____D__|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______|
[403]-[404] DLS Downloading Access Code / Panel ID Code (Enter 6 Hexadecimal Digits)
Opt Def. ON OFF
1
Opening After Alarm Keypad Ringback Enabled
9
Disabled
2
Future Use
9
3
SIA Uses Programmed Reporting Codes
9
SIA Uses Automatic Reporting Codes
4
Closing Confirmation Enabled
9
Closing confirmation Disabled
5-6
Future Use
9
7
Contact ID Uses Programmed Reporting Codes
9
Contact ID Uses Automatic Reporting Codes
8
Future Use
9
Opt Def. ON OFF
1
Contact ID Partial Closing Identifier is “5”
9
Contact ID Partial Closing Identifier is “4”
2
Alarm Communications Enabled During Walk Test*
9
Alarm Communications Disabled During Walk Test
3
9
Communication Cancelled Message Enabled (ON for SIA CP-01)
Communication Cancelled Message Disabled
4
Call Waiting Cancel Enabled**
9
Call Waiting Cancel Disabled
5
Future Use
9
6
AC Failure Transmission Delay is in Hours
9
AC Failure Transmission Delay is in Minutes
7
Number of Dialing Attempts is 1 for Residential Dial
9
Residential Dialing Attempts is 5
8
Future Use
9
Opt Def. ON OFF
1
Answering Machine/Double Call Enabled
9
Answering Machine/Double Call Disabled
2
9
User Can Enable DLS Window
User Cannot Enable DLS Window
3
Call Back Enabled
9
Call Back Disabled
4
User Initiated Call Up Enabled
9
User Initiated Call Up Disabled
5
Future Use
9
6
300 Baud Panel Call up
9
110 Baud Panel Call up
7
Future Use
9
8
Future Use
9
[403] Downloading Access Code [404] Panel ID Code
SCW9045 Default = 904500/904500
|_______|_______|_______|_______|_______|_______| |_______|_______|_______|_______|_______|_______|