50
[347] Delinquency Programmed amount of time (days or hours) for delinquency has
expired without zone activity, or without system being armed
MA/R (6) 54*** CD-00
[347] Wireless Device Low Battery
Trouble/Rest.
Wireless zones, panic pendants, wireless keys have low battery/
all low batteries restored
MA/R (3) 84 XT-00/XR-00
XT-ZZ/XR-ZZ****
[347] Installer Lead In Installers mode has been entered MA/R (6)27 LB-00
[347] Installer Lead Out Installer’s mode has been exited MA/R (6)28 LS-00
[348] Walk Test End End of test T (6) A7 TE-00
[348] Walk Test Begin Beginning of test T (6) A7 TS-00
[348] Periodic Test Periodic system test transmission T (6) A2 RP-00
[348] System Test [*][6] bell/communications test T (6) A1 RX-00
* A/R = alarms/restorals; T/R = tampers/restorals; O/C = openings/closings; MA/R = miscellaneous alarms/restorals; T = test transmissions
** UU = user number (user01-16,40); ZZ = zone number (01-34).
*** Use the “Fail to close” event code [(4)54] to report closing or activity delinquency. Ensure the central station is aware that this code is used.
**** Zones are panic pendants are identified, wireless keys can be identified for openings and closings.
Section # Reporting Code Code Sent When...
Dialer
Direction*
Automatic
Contact ID
Codes
SIA Auto
Rep Codes**
Contact ID Zone Alarm/Restoral Event Codes
(as per SIA DCS: ‘Contact ID’ 01-1999):
Program any of these codes for zone alarms/restorals when using the
standard (non-automatic) Contact ID reporting format.
SIA Format Automatic Zone Alarm/Restoral Codes
Medical Alarms (1)34 Entry / Exit
(1)AA Medical (1)35 Day / Night
(1)A1 Pendant Transmitter (1)36 Outdoor
(1)A2 Fail to Report In (1)37 Tamper
Fire Alarms (1)38 Near Alarm
(1)1A Fire Alarm General Alarms
(1)11 Smoke (1)4A General Alarm
(1)12 Combustion (1)43 Exp. module failure
(1)13 Water Flow (1)44 Sensor tamper
(1)14 Heat (1)45 Module Tamper
(1)15 Pull Station (1)4A Cross Zone Police Code
(1)16 Duct 24 Hour Non-Burglary
(1)17 Flame (1)5A 24 Hour non-Burg
(1)18 Near Alarm (1)51 Gas detected
Panic Alarms (1)52 Refrigeration
(1)2A Panic (1)53 Loss of Heat
(1)21 Duress (1)54 Water Leakage
(1)22 Silent (1)55 Foil Break
(1)23 Audible (1)56 Day Trouble
Burglar Alarms (1)57 Low bottled Gas level
(1)3A Burglary (1)58 High Temp
(1)31 Perimeter (1)59 Low Temp
(1)32 Interior (1)61 Loss of Air Flow
(1)33 24 Hour
Zone Definition SIA Auto Rep
Codes*
Contact ID Auto
Rep Codes*
Delay 1 BA-ZZ/BH-ZZ (1) 3A
Delay 2 BA-ZZ/BH-ZZ (1) 3A
Instant BA-ZZ/BH-ZZ (1) 3A
Interior BA-ZZ/BH-ZZ (1) 3A
Interior Stay/Away BA-ZZ/BH-ZZ (1) 3A
Delay Stay/Away BA-ZZ/BH-ZZ (1) 3A
24-Hr. Supervisory US-ZZ/UR-ZZ (1) 5A
24-Hr. Supervisory Buzzer UA-ZZ/UH-ZZ (1) 4A
24-Hr. Burg BA-ZZ/BH-ZZ (1) 3A
24-Hr. Gas GA-ZZ/GH-ZZ (1) 51
24-Hr. Heat KA-ZZ/KH-ZZ (1) 58
24-Hr. Medical MA-ZZ/MH-ZZ (1) AA
24-Hr. Panic PA-ZZ/PH-ZZ (1) 2A
24-Hr. Emergency QA-ZZ/QH-ZZ (1) A1
24-Hr. Water WA-ZZ/WH-ZZ (1) 54
24-Hr. Freeze ZA-ZZ/ZH-ZZ (1) 59
Interior Delay BA-ZZ/BH-ZZ (1) 3A
Instant Stay/Away BA-ZZ/BH-ZZ (1) 3A
24-Hr. Non-latching Tamper TA-ZZ/TR-ZZ (3) 83
Night Zone BA-ZZ/BH-ZZ (1) 3A
Delayed 24-Hr. Fire (Wireless) FA-ZZ/FH-ZZ (1) 1A
Standard 24-Hr. Fire (Wireless) FA-ZZ/FH-ZZ (1) 1A
24-Hr. Auto Verified Fire (Wireless) FA-ZZ/FH-ZZ (1) 1A
* ZZ = zones 01-34