INSTALLATION GUIDE 503 PLATINUM
By choosing *Quick Start, the functions with a * will not be valid.
Version 5V-3
TABLE 2 FUNCTIONS PRESS LOCK PRESS UNLOCK PRESS MUTE PRESS START
2.01
Trunkpulse(pressunlock+aux)
*onlywhenusewithoption2.10
Regularpulse Latch when hold Latchtogglebytx 5 sec pulse
2.02
SlidingdoorAUX2(pressunlock1.5sec)
*rstsetoption2.10
Regularpulse Latch when hold Latchtogglebytx 5 sec pulse
2.03
SlidingdoorAUX1(pressAux1.5sec)
*rstsetoption2.10
Regularpulse Latch when hold Latchtogglebytx 5 sec pulse
2.04 Valetoverride Push button 6Timesfootbrakes
2.05 Fuel type selection Gas Diesel
2.06 Diesel type selection 8 sec 12 sec 15 sec 20 sec
2.07 When remote start door relock Disable Enable Enable after start
Unlockbeforeignition/
relockaftercranking
2.08 Numbers of tries for start attempt Onetry *Twotries *Threetries
2.09 *Turbomodetimeradjustment *45 sec default *60 sec *90 sec *120 sec
2.10 Auxiliaroutputselection Trunkreleaseoutput
Channelexpanderi.E.Sliding
doors,defrost,seatheateretc…
2.11 Keysense(whte/Green) Enable Disable Starttrigger
2.12
N/A N/A N/A N/A N/A
2.13 Telematicstart/stopwithseparatebutton Disable Enable
2.14 Re-arm when shut off Enable Disable
TABLE 3 FUNCTIONS PRESS LOCK PRESS UNLOCK PRESS MUTE PRESS START
3.01 Horn/sirensetting Horn Siren
3.02 Hornsetting Default Extended Extended-3msec Extended+3msec
3.03 Hornsirenconrmation Chirp enable Chirp on 2nd press Full mute Mute on unlock
3.04 Horn/sirenignitionmonitor Disable Enable
3.05 Startmodefortx Default Press Lock then Start Press Start twice
3.06
Safety auto relock with
alarm mode only
Enable Disable
Enable without alarm
(door input must be
connected)
3.07 Pulsebeforeignition 1.5sec 0.5sec 3 sec
3.08
Ignitionvaletmode
(on disarm mode only)
Disable Enable(Ignitionon5times)
3.09
*Manualtransmissionsetting
(see3.15&3.16)
*Auto shut off *Shut off by remote
FBOn/HBOn/FBOff/
KeyOff/Exit/Engshut
in 10sec
3.10 *Manualtransmissionsetting
With door lock Without door lock
3.11 Unlockdriverdoor Disable Enable With data mode only
3.12 Passkey output selection Passkey secure non-secure With data mode only
3.13 Protocol unlock while remote start Disable Enable With data mode only
3.14 *Manualsettingcrankingtime *Standard crank *Overcrank+2
3.15 Manualtransmission:unlockbeforeexit Enable Disable
3.16 Manual transmission: silent mode Disable Enable
TABLE 4 FUNCTIONS PRESS LOCK PRESS UNLOCK PRESS MUTE PRESS START
4.01 Passkeyoutputprogrammingoptions Standard Staygroundwithignition 2
nd
ignition 2
nd
start
4.02
Rearmwireoutputprogramming
options
2003 Gm disable
Enable to remote lock with
enginerunning
4.03 Domelightby-pass Disable Enable
4.04 Domelightdiagnostic(4chirps) Enable Disable
4.05 *Minimumcrankingtimeadjustments *0.7sec *0.9sec *1.2sec *1.5sec
4.06 *Maximumcrankingtimeadjustments * 10 sec *3.5sec
4.07 Parkinglightoffafter3minutes Disable Enable
4.08 Mute button selection Mute Trunk Stop
4.09 Acc relay selection ACC + Ignition+ Start + Passkey +
4.10 Arm pulse Regular Before lock pulse
4.11 Disarm/unlock Regular GWR+Ign GWR+Acc+Ign GWR + Acc
4.12 N/A N/A N/A N/A N/A
4.13
Engineshutoffwhenvoltagedrop
below
13.25V 13V 12.75V 12.5V
4.14 Tachlesscrankingadjustment Default 5% Less 5% More 10% More