Dune 4WD Fridge/Freezer Dune 4WD Fridge/Freezer
14 15
7. Technical Data6. Error Codes and Troubleshooting
E5 Overheat
Warning
Blocked vents or
through compres-
sor compartment
Ambient tem-
perature too high
• Fan fault
1. Check that the vents are not
blocked during operation. A
spacing of 100mm around the
compressor vents is needed for
proper ventilation.
2. Wipe down the compressor vents
to improve circulation.
3. -
perature is within the recommend-
ed operating temperature of the
device.
4. If still unresolved, contact your
local Anaconda store for
assistance.
E6
LL
HH
Temperature
sensor error
Temperature
sensor may be
damaged or loose
Contact your local Anaconda store
for assistance.
Troubleshooting
e unit is not turning on
Check whether the unit is powered on at the control panel
Check power cable fuse
Check device fuse
Poor refrigeration performance
products are too tightly packed, poor air circulation results in slower cooling
Poor ventilation (allow 100mm around all vents)
Check lid seals for dust, debris or damage. Clean seals regularly for proper
sealing.
for device
To increase refrigeration performance, cool products in home refrigerator/
freezer before placing in the device
Refrigerant changes from a liquid to a vapor while it passes through the evaporator
plates – this change in phase is what results in cooling. Hearing the sound of liquid
flowing inside your device means that the unit is working as expected.
Rattling or unusual noise during operation
Check that the refrigerator is placed on a level surface
Internal parts may have come loose – contact your local Anaconda store for
assistance
7. Technical Data
-
-
-
Note:
1. The cooling compartment has varying temperature zones across compart
ment depth due to the energy absorbed by the refrigerant as it passes
through the evaporator plates. This is unavoidable and a common phenom
enon in portable chest fridge freezers. A temperature differential of 3-5°C
may be assumed due to this phenomenon.
2.
middle of the cabinet.
3. The minimum temperature displayed on the control panel cannot be at
tained for the single zone models if the ambient temperature is greater than
32°C (for dual zone models, this is true for the small compartment set to
–22°C and large compartment set to +4 °C).
Model 45L Single Zone 75L Dual Zone 95L Dual Zone
Internal Volume 45L 75L 95L
Dimensions (mm)
H: 460
W: 455
L: 650
H: 460
W: 540
L: 962
H: 460
W: 485
L: 900
Weight (kg) 20.5kg 27.8kg 30.6kg
Input Voltage 12/24V DC 220-240V 50/60Hz AC
Rated Current DC:
4.6A@12V
2.3A@24V
AC:
0.3A
DC:
4.6A@12V
2.3A@24V
AC:
0.3A
DC:
5.5A@12V
2.75A@24V
AC:
0.3A
Climate Class N, ST, T
USB 5V, 2A 5V, 2A 5V, 2A
Refrigerant R134a
Refrigerant Charge 49g 59g 74g
Cooling Range -22ºC~10ºC