1. Set the thermostat to lowest setting.
2. Turn off all electric power to the appliance.
3. This appliance is equipped with an ignition device
which automatically lights the burner. Do not
attempt to light the burner by hand.
4. Remove burner access panel.
5. Depress gas control knob slightly and turn
clockwise to OFF position.
OPERATING INSTRUCTIONS
NOTE: Knob cannot be turned to OFF unless
knob is depressed slightly. Do not force.
6. WARNING: Wait five (5) minutes to allow any
gas in the combustion chamber to vent. If
you then smell gas in the appliance area or
near the floor, do not touch any electrical
switch, do not use the phone. Leave the
building immediately and call your gas
supplier. If your gas supplier cannot be
reached, call the fire department. Failure to
do so may result in a fire or explosion. If
you dont smell gas, go to next step.
7. Turn gas control knob counterclockwise
to ON.
8. Turn on all electric power to the appliance.
9. Set thermostat to desired setting.
10. After visually inspecting the flame, replace the
lower front panel.
11.WARNING: if the appliance will not operate
after several tries, turn the gas control knob
to OFF and call your service technician or
gas supplier.
TO TURN OFF APPLIANCE
1. Set the thermostat to lowest setting.
2. Turn off all electric power to the appliance if
servicing is to be performed.
3. Depress gas control knob slightly and turn
clockwise to OFF position. Do
not force.
23
FIG. 13

Other manuals for Dunkirk XEB-4