EasyManua.ls Logo

Duplo DP-S850 - Detection Timing

Duplo DP-S850
298 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
209
c HELP Mode Function and Operation Procedures
chap.7
¡ Operation procedure
1.
Check that the master is wound around the drum. Then enter
005
by the
NUMERIC
keys and then press the
(PRINT)
key.
Call the HELP mode
H-005
.
3.
2
Press the
(MASTER MAKING)
key.
The drum stops at the
drum master detected position
(the drum stop
position), at the
drum master undetected position
(the leather part at
the screen back end) and
below the drum master sensor
, in order.
Check operation.
4.
step 5.
a
Press the
(STOP)
key.
2.
Touch the
(
arrow
)
on the screen lower right twice to switch to Page 3.
Change the screen.
(3)
Adjusting/Checking the Drum Section
(4 pages in total)
Page 3 :
2
Adjustment / Check
Drum master sensor
¡
Normally, the adjustment value of the drum master sensor is 80 ± 10.
NOTE :
Check the drum master sensor.
Checking the sensor.

Table of Contents