1
Shallow Well Jet Pumps
Cast Iron Models DSW500, DSW750 & DSW1000
Stainless Steel Models DSW500SS, DSW750SS &
DSW1000SS
Operating & Installation Instructions
Please read these instructions carefully. Failure to comply with instructions and designed operation of this system may void the warranty.
Your pump has been carefully packaged at the factory to prevent damage during shipping. However, occasional damage may occur due
to rough handling. Carefully inspect your pump for damage that could cause failure. Report any damage to your carrier or your point of
purchase.
Shallow well jet pumps are single stage domestic water pumps designed for pumping potable water in applications where the water is
located less than 25 feet vertically from the pump. A pressure switch is a standard feature. The shallow well pump can be mounted to
either a precharged horizontal pressure tank or used with a precharged free standing pressure tank. The pumps can also be used with
conventional air to water tanks.
General Safety Information
1. Know the pump application, limitations and potential hazards.
- Always install a pressure relief valve to match the system pressure rating and the maximum flow rate.
- Do not pump flammable or explosive fluids such as gasoline, fuel oil, kerosene, etc. Failure to follow this warning can
result in personal injury and/or property damage and will void the warranty.
- Disconnect power and relieve all pressure from the system before attempting to install, service, relocate or perform any
maintenance. Lock the power disconnect in the open position. Tag the power disconnect to prevent unexpected
application of power. Install a screen around the inlet pipe to prevent entrapment of swimmers (if applicable).
#51451EF Rev. 10/09
Cast Iron Models
Stainless Steel Models
CLICK ANYWHERE on THIS PAGE to RETURN TO WATER PUMP WIRING & REPAIR at InspectApedia.com

Questions and Answers

Summary

Operating and Installation Instructions

General Safety Information

Key safety precautions for pump installation and operation, including electrical and fluid handling hazards.

Pre-installation Tanks and Components

Details on conventional and precharged tanks, pressure switches, well considerations, location, piping, and motor settings.

Shallow Well Installation

Drilled Well Installation

Step-by-step instructions for installing the pump in a drilled well, including foot valve placement.

Driven Well Installation

Guidance for installing the pump in a driven or sandpoint well, mentioning foot valve alternatives.

Typical Installation Diagram

Diagram illustrating a typical shallow well pump installation setup with key components.

Alternative Installation Methods

Dug Out, Cistern, Lake and Spring Installation

Instructions for installing the pump in various water sources like dug outs, cisterns, lakes, and springs.

Pump Connections to Storage Tanks

Details on connecting shallow well pumps to conventional and precharged storage tanks.

Electrical Wiring and Safety

Recommendations for proper electrical wiring, grounding, and voltage selection for the pump.

Pump Operation and Maintenance

Priming the Shallow Well Pump

Step-by-step procedure for priming the pump to ensure proper operation and prevent damage.

Draining and Restarting Procedures

Instructions on how to drain the pump and tank, and important steps for restarting the pump.

Precharged Tank and Lubrication

Guidance on checking/adjusting precharged tank pressure and information on pump lubrication.

Troubleshooting Guide

Motor and Water Supply Issues

Diagnoses for motor not running, no water supply, and motor overload.

Performance and Pressure Problems

Troubleshooting for low water supply, low pressure, and frequent pump cycling.

Air in System and Noise Issues

Addresses air in the water supply, low pressure delivery, and pump noise causes.

Diagnosing Waterlogged Tanks

Conventional Tank Issues

Explains how to diagnose and resolve issues with conventional waterlogged tanks.

Precharged Tank Issues

Details how to identify and resolve issues with waterlogged precharged tanks, typically bladder failure.

Product Guarantee

Warranty Terms and Claim Procedure

Details the two-year warranty period, how to claim it, and limitations on manufacturer liability.