Introduction
This pump has been carefully packaged, inspected and tested to ensure safe operation and delivery. Before installing the pump, check to
see if any damage has occurred to the pump from rough handling. Notify the dealer from whom you purchased the pump if any damage
has occurred.
This sewage pump is suitable for pumping sewage, effluent, wastewater, groundwater and other non-explosive, non-corrosive liquids with
up to 2" (51 mm) solids. The pump includes a wide angle float switch that turns the pump on and off as the fluid level rises and falls.
Safety Instructions
The following safety rules should be followed to avoid serious injury or property damage:
Always remove the plug from the electrical outlet before servicing this pump.
1. Check with your local electrical and plumbing codes to ensure you comply with the regulations. These codes have been designed
with your safety in mind. Be sure to comply with them.
2. We recommend that a separate circuit be led from the home electrical distribution panel and properly protected with a fuse or a
circuit breaker. We also recommend that a ground fault circuit be used. Consult a licensed electrician for all wiring
.
3. Do not stand in water when connecting or disconnecting power cord from outlet.
4. This product should be connected to a three prong grounded outlet equipped with a ground fault circuit interrupter.
5. Do not pump flammable liquids with this pump as an explosion or fire could result.
6. Vent sewage or septic tank according to local codes.
7. Do not run this pump dry. Running your pump without water will damage the mechanical seal, reduce the life of the pump and void
the warranty.
8. Do not touch metal motor housing for at least 30 minutes after pump has operated. A severe burn will result if pump is not allowed to
cool. Do not lift the pump by the electrical cord.
9. This product does not require lubrication. A special oil has been put into the motor housing at the factory for lifetime lubrication of the
bearings. Use of any other oil can cause damage and void the warranty.
Installation Instructions
1. Install pump on a hard, level surface (cement, asphalt, etc.). Never place pump directly on earth, clay or gravel surfaces.
2. Install pump in a basin of at least 16 inches (405 mm) diameter and 24 inches (610 mm) depth.
#51448EF 8/07
Submersible Wastewater Pump
Models DSBF300 & DSBW300
Operating & Installation Instructions
Question and Answer IconNeed help?

Do you have a question about the Duro Professional Series and is the answer not in the manual?

Summary

Introduction

Safety Instructions

Local Codes Compliance

Check local electrical and plumbing codes for regulatory compliance before installation.

Electrical Circuit Recommendations

Use a separate circuit with fuse/breaker and GFCI for safety.

Water Safety During Connection

Avoid standing in water when connecting/disconnecting the power cord.

Grounding and GFCI Requirement

Connect to a three-prong grounded outlet with GFCI.

Flammable Liquid Prohibition

Do not pump flammable liquids to prevent explosion or fire.

Ventilation of Tanks

Vent sewage or septic tanks according to local codes.

Dry Running Prohibition

Avoid running the pump dry to prevent seal damage and voiding warranty.

Cooling Period for Motor Housing

Allow 30 minutes for motor housing to cool before touching after operation.

Maintenance-Free Lubrication

Pump has lifetime lubrication; do not add other oils.

Installation Instructions

Pump Surface Installation

Install pump on a hard, level surface like cement or asphalt.

Basin Requirements

Install pump in a basin at least 16 inches diameter and 24 inches depth.

Piping and System Components

Piping for Effluent Applications

Use ABS, PVC, or galvanized steel piping, 1½" minimum for 3/4" solids.

Piping for Sewage Applications

Use ABS, PVC, or galvanized steel piping, 2" minimum for 2" solids (DSBW300).

Check Valves & Air Locking

Check local codes for check valves; drill relief hole to prevent air locking.

Basin Cover and Vent

Sealed cover and vent are compulsory for sewage, optional for sump water.

Electrical Information

Automatic Thermal Overload Protection

Motor has a built-in protector that cuts off power before overheating.

Liquid Level Control Operation

Float switch controls automatic pump operation; adjust tether length.

Maintenance

Keep Pump Clean

Ensure the pump inlet screen is kept clean and free of debris.

Cleaning Frequency

Cleanings should occur often, especially for pumps that run constantly.

Float Inspection

Inspectors should ensure the float is not tangled or jammed.

Jammed Float Issues

A pump with a jammed float is useless; ensure it can turn on and shut off.

Pump Testing Procedure

Test pump by pouring water into the pit to ensure it activates and expels water.

Professional Assistance

Seek professional help if the pump does not activate.

Trouble Shooting Checklist

Pump Not Running or Humming

Check plug connections, breaker/fuse, liquid level control, and thermal overload.

Pump Continuously Running

Ensure the liquid level control is not caught on basin sides or pump.

Insufficient Pumping Performance

Check for air locking, plugged impeller/suction, valve issues, or undersized piping.

Frequent Pump Cycling

Verify the check valve is not stuck open, which can cause short cycling.

Guarantee

How To Claim Warranty

Return defective units or parts to your dealer with serial number and proof of purchase.