EasyManuals Logo

Dustcontrol DC Tromb 400 User Manual

Dustcontrol DC Tromb 400
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #12 background imageLoading...
Page #12 background image
DC Tromb 400a/c/L- 12
Part No 9480-H
2018-02-23
(espe-cially lter) the machine could leak out
unhealthy dust which can cause personal inju-
ries.
This appliance is not intended for use by
persons (including children) with reduced
physical, sensory or mental capabilities, or
lack of experience and knowledge, unless they
have been given supervision or instruction
concerning use of the appliance by a person
responsible for their safety. Children should be
supervised to ensure that they do not play with
the appliance.
DC Tromb 400c DC Tromb 400a DC Tromb 400L
HxWxL mm 1390 x 560 x 697 1390 x 560 x 697 1390 x 560 x 697
HxWxL in. 55 x 22 x 27 55 x 22 x 27 55 x 22 x 27
Weight 46 kg/101 lb 50 kg/110 lb 48 kg/106 lb
Inlet X 76 mm/3 i n. X 76 mm/3 i n. X 76 mm/3 i n.
Hose length (Ø 50 mm) 5 m/16.4ft 5 m/16.4ft 5 m/16.4ft
Collection sack/container 20 l 40 l exible
Flow max, open inlet EU 393 m
3
/h 393 m
3
/h 393 m
3
/h
Flow max, open inlet UK 330 m
3
/h/194 ft
3
/m 330 m
3
/h/194 ft
3
/m 330 m
3
/h/194 ft
3
/m
Flow max, open inlet USA/CAN 320 m
3
/h/188 ft
3
/m 320 m
3
/h/188 ft
3
/m 320 m
3
/h/188 ft
3
/m
Flow max fan EU 420 m
3
/h 420 m
3
/h 420 m
3
/h
Flow max fan UK, USA/CAN 360 m
3
/h/212 ft
3
/m 360 m
3
/h/212 ft
3
/m 360 m
3
/h/212 ft
3
/m
Neg pressure, max EU 22 kPa 22 kPa 22 kPa
Neg pressure, max UK 21 kPa 21 kPa 21 kPa
Neg pressure, max USA/CAN 20 kPa 20 kPa 20 kPa
Power consumption EU 3000 W 3000 W 3000 W
Power consumption UK 2680 W 2680 W 2680 W
Power consumption USA/CAN 2100 W 2100 W 2100 W
Fine lter polyester, area 2.5 m
2
/27 ft.
2
2.5 m
2
/ 27 ft.
2
2.5 m
2
/ 27 ft.
2
Degree of separation ne lter
(EN 60335-2-69, Class M) 99.9 % 99.9 % 99.9 %
Filter area, micro lter 2.2 m
2
/23,7 ft.
2
2.2 m
2
/23,7 ft.
2
2.2 m
2
/23,7 ft.
2
Degree of separation micro lter
(EN 60335-2-69, Class H) 99.995 % 99.995 % 99.995 %
(EN 1822-1) HEPA H13 HEPA H13 HEPA H13
Soundlevel 70 dB(A) 70 dB(A) 70 dB(A)
Safety Considerations
This machine is intended for commercial use
only, for example in hotels, schools, hospitals,
factories,shops, o󰀩ces, construction and ren-
tal businesses.
10. Transport
The machine’s discharge system and cyclone
must be emptied before the machine is trans-
ported.
Technical Data

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dustcontrol DC Tromb 400 and is the answer not in the manual?

Dustcontrol DC Tromb 400 Specifications

General IconGeneral
BrandDustcontrol
ModelDC Tromb 400
CategoryVacuum Cleaner
LanguageEnglish

Related product manuals